DVR® Crosslock 1318-22-126
Ref 131822126
DVR Crosslock 1318-22-126 (131822126) is an orthopaedic fixation plate (EU MDD Class IIb; FDA Class II; FDA product code HRS, Plate, fixation, bone) made by Biomet Orthopedics, Inc., registered in EUDAMED on 24 Oct 2026 (Basic UDI-DI B-00887868446313), cleared under FDA 510(k) K133939 on 1 Apr 2014 and listed in FDA GUDID since 17 Jul 2020 (UDI-DI 00887868446313), active as of 7 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00887868446313 00887868446313 | Date24 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868446313 | Date17 Jul 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK133939 | Date1 Apr 2014 | StatusActive |
Official records
- EUDAMED public site B-00887868446313
- AccessGUDID record 00887868446313
- FDA 510(k) database K133939
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00887868446313 registered 24 Oct 2026 Active
- FDA 510(k) K133939 decided 1 Apr 2014 Active
- FDA GUDID UDI-DI 00887868446313 listed 17 Jul 2020 Listed
Recalls
-
- Terminated Z-0810-2022
Packaging of various implants may not have sufficient adhesion on all sides, leading to loss of sterile barrier integrity. Use of product poses risk of infection, leading to surgical intervention, and/or extension of surgery to find another part.
-
- Terminated Z-1082-2016
Components of the DVR ePAKs can oxidize during shipment and storage prior to use. A delay in surgery, less than 30 minutes, may occur if the surgical staff proceeds to re-sterilize the product. If oxidative material would flake off a component contained within the ePAK and enter the surgical field/wound an inflammatory reaction may occur. The inflammatory reaction may result in a foreign body reaction and/or metal hypersensitivity. Oxidized components have failed cytotoxicity testing.
Timeline
- Cleared FDA 510(k) K133939
- Recall initiated FDA recalls Z-1082-2016
- Listed FDA GUDID 00887868446313
- Recall initiated FDA recalls Z-0810-2022
- Registered EUDAMED B-00887868446313
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Dvr® Crosslock
- Generic name
- Orthopaedic fixation plate, non-bioabsorbable
- Device name
- DVR Crosslock Plates Extra Long Plate L & R sterile
- Model / Ref / Catalog
- 131822126, 1318-22-126
- Primary DI / UDI-DI
- 00887868446313
- Basic UDI-DI
- B-00887868446313
- 510(k) Number
- FDA product code
- HRS
- EMDN code
- P09120503 Osteosynthesis screw-plate systems
- GMDN term
- Orthopaedic fixation plate, non-bioabsorbable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3030
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 131822126 | 1318-22-126 |
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.
- "1.0MM" SYSTEM 99-7403 by BIOMET MICROFIXATION, INC
- Arthrex® AR-18724P-23 by Arthrex, Inc.
- Arthrex® AR-7657-14 by Arthrex, Inc.
- LOQTEQ® PH 3510-03-2 by aap Implantate AG
- STERILE TRAC SYSTEM 12 PACK SP-ST-1005-12 by BIOMET MICROFIXATION, INC
- LOQTEQ® PH 3541-11-2 by aap Implantate AG
- 181-10006 by TDM Co., Ltd.
- MEDPLATES 36.DS.1505.0 by RAMED MEDIKAL ITHALAT IHRACAT VE PAZARLAMA LIMITED SIRKETI
- 00-2358-012-03 by Zimmer, Inc.
- Ortholox® Locking Periprosthetic Support Proximal Femur Cable-Plate, Left - 4 Holes, 4.5/5.0mm 31-055-L004 by ORTOLOG MEDİKAL SANAYİ VE TİCARET ANONİM ŞİRKETİ