Skip to content

DVR® Crosslock 1318-20-051

by Biomet Orthopedics, Inc.

Ref 131820051

DVR Crosslock 1318-20-051 (131820051) is an orthopaedic fixation plate (EU MDD Class IIb; FDA Class II; FDA product code HRS, Plate, fixation, bone) made by Biomet Orthopedics, Inc., registered in EUDAMED on 24 Oct 2026 (Basic UDI-DI B-00887868446245), cleared under FDA 510(k) K133939 on 1 Apr 2014 and listed in FDA GUDID since 17 Jul 2020 (UDI-DI 00887868446245), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K133939

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00887868446245 Basic UDI-DI 00887868446245UDI-DIDate24 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00887868446245 UDI-DI Date17 Jul 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK133939 Date1 Apr 2014DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00887868446245 registered 24 Oct 2026 Active
  • FDA 510(k) K133939 decided 1 Apr 2014 Active
  • FDA GUDID UDI-DI 00887868446245 listed 17 Jul 2020 Listed

Recalls

2 recalls · FDA

    • Terminated Z-0810-2022 FDA Class II initiated 14 Feb 2022 on shared 510(k) K133939

    Packaging of various implants may not have sufficient adhesion on all sides, leading to loss of sterile barrier integrity. Use of product poses risk of infection, leading to surgical intervention, and/or extension of surgery to find another part.

    • Terminated Z-1082-2016 FDA Class II initiated 29 Jan 2016 on shared 510(k) K133939

    Components of the DVR ePAKs can oxidize during shipment and storage prior to use. A delay in surgery, less than 30 minutes, may occur if the surgical staff proceeds to re-sterilize the product. If oxidative material would flake off a component contained within the ePAK and enter the surgical field/wound an inflammatory reaction may occur. The inflammatory reaction may result in a foreign body reaction and/or metal hypersensitivity. Oxidized components have failed cytotoxicity testing.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K133939
  2. Recall initiated FDA recalls Z-1082-2016
  3. Listed FDA GUDID 00887868446245
  4. Recall initiated FDA recalls Z-0810-2022
  5. Registered EUDAMED B-00887868446245

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Dvr® Crosslock
Generic name
Orthopaedic fixation plate, non-bioabsorbable
Device name
DVR Crosslock Plates Extra Narrow Plate L & R sterile
Model / Ref / Catalog
131820051, 1318-20-051
Primary DI / UDI-DI
00887868446245
Basic UDI-DI
B-00887868446245
510(k) Number
FDA product code
HRS
EMDN code
P09120503 Osteosynthesis screw-plate systems
GMDN term
Orthopaedic fixation plate, non-bioabsorbable
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
888.3030
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
131820051
GUDID
1318-20-051
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)