Skip to content

Endoskeleton® TCS 5080-1611

by Titan Spine, Inc.

Endoskeleton TCS 5080-1611, a spinal implant trial (FDA Class II) made by Titan Spine, Inc., was cleared under FDA 510(k) K142940 on 28 Jan 2015 and listed in FDA GUDID on 30 Sep 2019 (UDI-DI 00191375036340); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 2.

Active United States. Also listed in GUDID (US), not in commercial distribution.

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

510(k) K142940

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00191375036340 UDI-DI Date30 Sep 2019ListedStatusListed GUDID: not in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK142940 Date28 Jan 2015DecidedStatusActive

Official records

From the FDA record

Device description
Trial, Parallel, Large, 11mm
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K142940 decided 28 Jan 2015 Active
  • FDA GUDID UDI-DI 00191375036340 listed 30 Sep 2019 Listed

Recalls

2 recalls · FDA

    • Terminated Z-2327-2015 FDA Class II initiated 20 Jul 2015

    Titan Spine is recalling specific Endoskeleton TCS Integrated Locking Bone Screw Assembly due to the locking bone screw collars not 'locking'.

    • Terminated Z-1324-2015 FDA Class II initiated 20 Feb 2015

    The TCS Straight Hexlobular #6 Drivers (5210-1004) tip sheared off during use in procedures that involved patients with dense bones. As a result of this malfunction, Titan Spine, LLC is removing all of the TCS Straight Hex lobular #6 Drivers (5210-1004) Lot# G150101 from the field.

Timeline

4 dated events

  1. Cleared FDA 510(k) K142940
  2. Recall initiated FDA recalls Z-1324-2015
  3. Recall initiated FDA recalls Z-2327-2015
  4. Listed FDA GUDID 00191375036340

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Endoskeleton® Tcs
Generic name
Spinal implant trial
Model / Ref / Catalog
5080-1611
Primary DI / UDI-DI
00191375036340
510(k) Number
FDA product code
ODP, OVE
GMDN term
Spinal implant trial
Device class
Class II
Regulation number
888.3080
GUDID distribution status
Not in Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
Size
Height — 11 Millimeter
Width — 18 Millimeter
Depth — 16 Millimeter

Similar devices

Other devices filed under FDA product code ODP (Intervertebral fusion device with bone graft, cervical).

Other devices from Titan Spine, Inc.

See all devices from Titan Spine, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)