Flexiview 8800 Digital Mobile Imaging System

by Ge Oec Medical Systems

510(k) K003837

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK003837 Date12 Mar 2001ClearedStatusActive

Recalls

9 recalls · 2 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-2279-2023 FDA Class II initiated 15 May 2023
    • Ongoing Z-2275-2023 FDA Class II initiated 15 May 2023

    Image intensifiers on systems, used to provide fluoroscopic/digital spot images can become detached if the systems encounter a large impact force when moved, which may result in the image intensifier falling, which could lead to injuries such as fractures, hematoma, contusion, bruise, pain.

    • Terminated Z-1469-2017 FDA Class II initiated 21 Feb 2017

    OEC FlexiView 8800 workstation power cable assembly issue which can result in a loss of imaging functionality due to intermittent power cord failures.

    • Terminated Z-0194-2015 FDA Class II initiated 3 Oct 2014

    GE Healthcare initiated a field correction because prior revision of components were potentially installed on certain OEC 9800, FlexiView 8800, OEC MiniView 6800 and OEC UroView 2800 systems.

    • Terminated Z-2027-2012 FDA Class II initiated 19 Nov 2007

    Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. GE OEC recalled imaging devices OEC 9900, OEC 9800, and OEC 8800 as a result of an FDA inspection identifying that the vertical lift column power supply in the mainframe C-arm is defective and subject to early life failure.

    • Terminated Z-2221-2012 FDA Class II initiated 19 Oct 2007 on shared 510(k) K003837

    X-ray units did not meet manufacturer's specification for linearity.

    • Terminated Z-0850-2007 FDA Unclassified (pre-2012) initiated 12 Jun 2007 on shared 510(k) K003837

    X-ray systems were not configured to display Air Kerma Rate and Cumulative Air Kerma.

    • Terminated Z-0678-2007 FDA Unclassified (pre-2012) initiated 1 Mar 2007 on shared 510(k) K003837

    During routine service, primary and/or secondary collimators may not have been properly reinstalled.

    • Terminated Z-2065-2012 FDA Class I initiated 20 Nov 2006

    Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. The OEC 8800 Flexview was recalled in November 2006 due to several intermittent potential safety issues including navigation tracking inaccuracy, system lok-up, incorrect image display, incorrect dose area calculated air kerma in "film mod

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
OXO
Device Class
Class II
Regulation
21 CFR Part 892.1650
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent