Galaxy System GAL-001
Galaxy System GAL-001 is a flexible video bronchoscope (FDA Class II; FDA product code EOQ, Bronchoscope (Flexible Or Rigid)) made by Noah Medical Corp., cleared under FDA 510(k) K223144 on 1 Mar 2023 and listed in FDA GUDID since 28 Feb 2025 (UDI-DI 00850048825048), active as of 22 Oct 2026. 5 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
5 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00850048825048 | Date28 Feb 2025 | StatusListed |
| United States | FDA 510(k)SESE | NumberK223144 | Date1 Mar 2023 | StatusActive |
Official records
- AccessGUDID record 00850048825048
- FDA 510(k) database K223144
From the FDA record
- Device description
- The Galaxy System is designed with the intent to enable articulation and precise control of a flexible, single-use disposable bronchoscope under continuous and direct control by a physician operator. The Galaxy System™ includes full procedure navigation that integrates a pre-operative computed tomography scan to display scope tip location relative to the pre-operative scan anatomy. Additionally, Galaxy integrates a tomosynthesis spin to update the scope and target position to overcome any changes in anatomy not reflected in the pre-op CT scan.
- MRI safety
- MR Safe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K223144 decided 1 Mar 2023 Active
- FDA GUDID UDI-DI 00850048825048 listed 28 Feb 2025 Listed
Recalls
-
- Ongoing Z-0598-2026
Due to Users not having access to the Instructions for Use/User Manual due to it being password protected.
-
- Ongoing Z-0742-2025
Bronchoscopic visualization system power supplies have defective semiconductor components that may fail unexpectedly, which could result in an aborted procedure since it is a non recoverable failure. Manual removal of the bronchoscope when the system is not functioning can increase the chance of injury to the tissues of the lung as the scope is withdrawn including the possibility of pneumothorax.
-
- Ongoing Z-0693-2025
Bronchoscopic system uninterruptable power may have defective component, may cause power supply short circuit/trip protective circuit breakers causing sudden, unrecoverable power loss, which could occur while system is on mains or internal battery power; if during procedure, could cause interrupted/aborted procedure, may necessitate manual removal, which could lead to lung injury/pneumothorax.
-
- Ongoing Z-0679-2025
Not all biopsy tools meant to fit bronchoscope channel (2.1mm inner diameter/length greater or equal to 1100mm) will pass through if scope channel positioned in sharp bend (approx. greater than 100-deg.), excessive force may result in tissue injury/pneumothorax; instruments with long rigid distal sections may exhibit insertion resistance when bronchoscope bending section significantly articulated.
-
- Ongoing Z-1734-2024
Due to a misaligned calibration of the wired controller that may result in unintended motion of the scope.
Timeline
- Cleared FDA 510(k) K223144
- Recall initiated FDA recalls Z-1734-2024
- Recall initiated FDA recalls Z-0693-2025
- Recall initiated FDA recalls Z-0679-2025
- Recall initiated FDA recalls Z-0742-2025
- Listed FDA GUDID 00850048825048
- Recall initiated FDA recalls Z-0598-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Galaxy System
- Generic name
- Flexible video bronchoscope, reusable
- Model / reference
- GAL-001
- Primary DI / UDI-DI
- 00850048825048
- FDA product code
- EOQ
- GMDN term
- Flexible video bronchoscope, reusable
- Device class
- Class II
- Regulation number
- 874.4680
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Safe