Infinity Mcable-Nellcor Oximax MS20668
by Draeger Medical Systems, Inc.
Ref MS20668Model 307028VK19K010
Infinity Mcable-Nellcor Oximax MS20668 is a patient monitoring system module (EU MDR Class IIb; FDA Class II) made by Draeger Medical Systems, Inc., registered in EUDAMED on 27 May 2026 (Basic UDI-DI 040486752307028VK19K010EB), cleared under FDA 510(k) K113798 on 22 Mar 2012 and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 04049098049665), active as of 23 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number040486752307028VK19K010EB 04049098049665 | Date27 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04049098049665 | Date24 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK113798 | Date22 Mar 2012 | StatusActive |
Official records
- EUDAMED public site 040486752307028VK19K010EB
- AccessGUDID record 04049098049665
- FDA 510(k) database K113798
Across registries
- EUDAMED Basic UDI-DI 040486752307028VK19K010EB registered 27 May 2026 Active
- FDA 510(k) K113798 decided 22 Mar 2012 Active
- FDA GUDID UDI-DI 04049098049665 listed 24 Oct 2015 Listed
Recalls
-
- Ongoing Z-1104-2021
The Infinity M540 patient monitor may randomly reboot due to an error to correctly transmit and read the header data of files in the memory of the device. Under this situation, the device will try to reboot to mitigate the error. The device will be available again for use within 30 seconds. If this error continues and the M540 reboots three times in a time span of 10 minutes, it will enter a fail-state. A fail-state will annunciate itself with a continuous sound to alert the user. The M540 will reset to factory default and the user can manually configure and readmit the patient to continue patient monitoring.
-
- Ongoing Z-0258-2020
Cybersecurity vulnerabilities may cause device to reboot, lose alarm functionality, and/or lose communication with cockpit and/or the Infinity Network.
-
- Terminated Z-1813-2018
Software anomaly resulting in the loss of patient settings and stored patient data.
-
- Terminated Z-1382-2018
The invasive pressure visual and audible alarms may not activate.
-
- Terminated Z-0942-2018
Dual Hemo MCable Pods with Revision Index (RI) 15 and 16, which are used with the Drger Infinity Acute Care System, may permit liquid ingress inconsistent with their IPX4 rating, which could potentially result in an incorrect measured value of invasive blood pressure.
-
- Terminated Z-2734-2017
Cockpits with revision index 06 or higher that contain 4GB RAM modules may not annunciate audio or visual alarms on the Cockpit and Central Station.
-
- Terminated Z-0714-2014
After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.
-
- Terminated Z-0939-2013
The displayed value for the invasive blood pressure measurement of the IACS was different than the actual patient values. Liquid ingress in the cable connection may cause inaccurate measurements. This can happen if the Dual Hemo MCable is used in a non-vertical position, a vertical position but upside down, or laying it on the floor or on the patient bed.
Timeline
- Recall initiated FDA recalls Z-0939-2013
- Recall initiated FDA recalls Z-0714-2014
- Listed FDA GUDID 04049098049665
- Recall initiated FDA recalls Z-2734-2017
- Recall initiated FDA recalls Z-0942-2018
- Recall initiated FDA recalls Z-1382-2018
- Recall initiated FDA recalls Z-1813-2018
- Recall initiated FDA recalls Z-0258-2020
- Recall initiated FDA recalls Z-1104-2021
- Registered EUDAMED 040486752307028VK19K010EB
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Infinity Mcable-Nellcor Oximax
- Generic name
- Patient monitoring system module, pulse oximetry
- Model / reference
- MS20668, 307028VK19K010
- Primary DI / UDI-DI
- 04049098049665
- Basic UDI-DI
- 040486752307028VK19K010EB
- Direct marketing DI
- 04049098049665
- 510(k) Number
- FDA product code
- DQA, MHX
- EMDN code
- Z1203020408 Pulse oximeters
- GMDN term
- Patient monitoring system module, pulse oximetry
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 870.2700, 870.1025
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under PULSE OXIMETERS.
- Handheld Pulse Oximeter SP-20 by Shenzhen Creative Industry Co., Ltd.
- rainbow SET 4183 by MASIMO CORPORATION
- Avant Pulse Oximeter System 9600-1403 by Nonin Medical, Inc.
- Dolphin CPD-10000 by MEDICAL TECHNOLOGY TRANSFER AND SERVICES COMPANY LIMITED
- M-50E by Beijing Choice Electronic Technology Co., Ltd.
- Rainbow 3777 by MASIMO CORPORATION
- Finger Oximeter H10 by Edan Instruments,Inc.
- NoninConnect Elite Finger Pulse Oximeter 10887-001 by Nonin Medical, Inc.
- Palmcare PRO (Li-Ion) 40.50-2300 by medical ECONET GmbH
- BERRY®贝瑞 BM1000A by SHANGHAI BERRY ELECTRONIC TECH CO., LTD.