Skip to content

Infinity Mcable-Nellcor Oximax MS20668

by Draeger Medical Systems, Inc.

Ref MS20668Model 307028VK19K010

Infinity Mcable-Nellcor Oximax MS20668 is a patient monitoring system module (EU MDR Class IIb; FDA Class II) made by Draeger Medical Systems, Inc., registered in EUDAMED on 27 May 2026 (Basic UDI-DI 040486752307028VK19K010EB), cleared under FDA 510(k) K113798 on 22 Mar 2012 and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 04049098049665), active as of 23 Oct 2026. 8 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K113798

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number040486752307028VK19K010EB Basic UDI-DI 04049098049665UDI-DIDate27 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04049098049665 UDI-DI Date24 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK113798 Date22 Mar 2012DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 040486752307028VK19K010EB registered 27 May 2026 Active
  • FDA 510(k) K113798 decided 22 Mar 2012 Active
  • FDA GUDID UDI-DI 04049098049665 listed 24 Oct 2015 Listed

Recalls

8 recalls · 2 ongoing · FDA

    • Ongoing Z-1104-2021 FDA Class II initiated 23 Dec 2020

    The Infinity M540 patient monitor may randomly reboot due to an error to correctly transmit and read the header data of files in the memory of the device. Under this situation, the device will try to reboot to mitigate the error. The device will be available again for use within 30 seconds. If this error continues and the M540 reboots three times in a time span of 10 minutes, it will enter a fail-state. A fail-state will annunciate itself with a continuous sound to alert the user. The M540 will reset to factory default and the user can manually configure and readmit the patient to continue patient monitoring.

    • Ongoing Z-0258-2020 FDA Class II initiated 13 Sep 2019

    Cybersecurity vulnerabilities may cause device to reboot, lose alarm functionality, and/or lose communication with cockpit and/or the Infinity Network.

    • Terminated Z-1813-2018 FDA Class II initiated 28 Mar 2018

    Software anomaly resulting in the loss of patient settings and stored patient data.

    • Terminated Z-1382-2018 FDA Class II initiated 21 Feb 2018

    The invasive pressure visual and audible alarms may not activate.

    • Terminated Z-0942-2018 FDA Class II initiated 4 Oct 2017

    Dual Hemo MCable Pods with Revision Index (RI) 15 and 16, which are used with the Drger Infinity Acute Care System, may permit liquid ingress inconsistent with their IPX4 rating, which could potentially result in an incorrect measured value of invasive blood pressure.

    • Terminated Z-2734-2017 FDA Class II initiated 6 Jun 2017

    Cockpits with revision index 06 or higher that contain 4GB RAM modules may not annunciate audio or visual alarms on the Cockpit and Central Station.

    • Terminated Z-0714-2014 FDA Class II initiated 10 Dec 2013

    After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.

    • Terminated Z-0939-2013 FDA Class II initiated 13 Dec 2012

    The displayed value for the invasive blood pressure measurement of the IACS was different than the actual patient values. Liquid ingress in the cable connection may cause inaccurate measurements. This can happen if the Dual Hemo MCable is used in a non-vertical position, a vertical position but upside down, or laying it on the floor or on the patient bed.

Timeline

11 dated events

  1. Recall initiated FDA recalls Z-0939-2013
  2. Recall initiated FDA recalls Z-0714-2014
  3. Listed FDA GUDID 04049098049665
  4. Recall initiated FDA recalls Z-2734-2017
  5. Recall initiated FDA recalls Z-0942-2018
  6. Recall initiated FDA recalls Z-1382-2018
  7. Recall initiated FDA recalls Z-1813-2018
  8. Recall initiated FDA recalls Z-0258-2020
  9. Recall initiated FDA recalls Z-1104-2021
  10. Registered EUDAMED 040486752307028VK19K010EB

1 earlier event are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Infinity Mcable-Nellcor Oximax
Generic name
Patient monitoring system module, pulse oximetry
Model / reference
MS20668, 307028VK19K010
Primary DI / UDI-DI
04049098049665
Basic UDI-DI
040486752307028VK19K010EB
Direct marketing DI
04049098049665
510(k) Number
FDA product code
DQA, MHX
EMDN code
Z1203020408 Pulse oximeters
GMDN term
Patient monitoring system module, pulse oximetry
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
870.2700, 870.1025
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under PULSE OXIMETERS.

Other devices from Draeger Medical Systems, Inc.

See all devices from Draeger Medical Systems, Inc. →

Properties

  • Measuring function
  • Manufacturing date
Other properties (23, all answered No)