Skip to content

INTERSTIM® Twist-Lock Cable 357664

by Medtronic, Inc.

Ref 357664

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

Not listed

EUDAMED holds no validity date

FDA recalls

3 ongoing

This device is named in the recall

Documents

None, self-declared

Class I: no certifier involved

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, GUDID, synced 24 Oct 2026. What this means

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0763000B00000206L Basic UDI-DI 00763000343309UDI-DIDate8 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00763000343309 UDI-DI Date6 Sep 2020ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Recalls

7 recalls · 3 ongoing · FDA

    • Ongoing Z-1704-2025 FDA Class II initiated 3 Apr 2025

    Evaluation handsets may not be able to communicate with the neurostimulator due to handsets having a faster processing speed than prior handsets. An inability to connect may cause the therapy to stop being delivered and a system error will be displayed. Patient may experience return of underlying disease symptoms (e.g. overactive bladder, urinary retention, or fecal incontinence) based on their response to stimulation during the evaluation period.

    • Ongoing Z-0372-2025 FDA Class II initiated 18 Sep 2024 on shared PMA P080025

    The Wireless Rechargers in the kits may be unable to enter a recharging session upon first use.

    • Ongoing Z-2365-2023 FDA Class II initiated 6 Jul 2023

    Lot of InterStim Self-Adhesive Ground Pad is being recalled due to the product being labeled with the incorrect expiration date.

    • Terminated Z-0998-2022 FDA Class II initiated 28 Feb 2022

    There is a software anomaly with the InterStim X Clinician software application with results in the data entered in the Patient Information fields not e retained and a " Data Lost" notification being displayed.

    • Terminated Z-1147-2015 FDA Class II initiated 9 Jan 2015 on shared PMA P080025

    Current labeling indicates that cycling improves device longevity in every programming scenario. However, enabling cycling at certain parameter settings may decrease the device battery longevity. With cycling enabled, longevity estimate displayed on the Model 8840Programmer may be inaccurate.

    • Terminated Z-0037-2008 FDA Unclassified (pre-2012) initiated 25 Jun 2007

    A software issue may cause a lower than expected battery capacity estimate when evaluating an InterStim II Implantable Neurostimulator (model 3058) with an N'Vision Clinician Programmer(Model 8840) before implant .

    • Terminated Z-0040-2008 FDA Unclassified (pre-2012) initiated 25 Jun 2007

    Software issue may cause false low battery alert to be displayed when interrogating an Interstim Implantable Neurostimulator (Model 3023) with an N'Vision Clinician Programmer (Model 8840), or with an Inter Stim iCon Patient Programmer (Model 3037).

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade Name
Interstim® EUDAMED
INTERSTIM® Twist-Lock Cable GUDID
Generic Name
Electrical-only medical device connection cable, reusable
Device Name
Twist-Lock Cable
Model / Reference
357664
Primary DI / UDI-DI
00763000343309
Basic UDI-DI
0763000B00000206L
FDA Product Code
EZW, QON
EMDN Code
U0780 Devices for the treatment of incontinence - accessories
GMDN Term
Electrical-only medical device connection cable, reusable
Device Class
Class I EUDAMED
Class III GUDID
Regulation Number
876.5270
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Size
Length — 64.0 Centimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device ClassEUDAMED
Class I
GUDID
Class III

Other devices from Medtronic, Inc.

See all devices from Medtronic, Inc. →

Properties

  • Single Use
  • Prescription Use
  • Lot / Batch Number

Other properties (21)

  • Sterile: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Expiration Date: No
  • Manufacturing Date: No