LUMINOS Lotus Max 11574100
Ref 11574100Model MDD_16_II b_ERLN H 127_Fluoro_digital_Lotus
LUMINOS Lotus Max 11574100 is a medical device (EU MDD Class IIb; FDA Class II; FDA product code OWB, Interventional fluoroscopic x-ray system; EMDN category fluoroscopy devices) made by Siemens Healthcare GmbH, registered in EUDAMED on 13 Oct 2026 (Basic UDI-DI B-04056869269931), cleared under FDA 510(k) K173639 on 2 Apr 2018 and listed in FDA GUDID since 1 Nov 2020 (UDI-DI 04056869269931), active as of 12 Nov 2026. 17 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
13 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04056869269931 04056869269931 | Date13 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04056869269931 | Date1 Nov 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK173639 | Date2 Apr 2018 | StatusActive |
Official records
- EUDAMED public site B-04056869269931
- AccessGUDID record 04056869269931
- FDA 510(k) database K173639
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as containing natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-04056869269931 registered 13 Oct 2026 Active
- FDA 510(k) K173639 decided 2 Apr 2018 Active
- FDA GUDID UDI-DI 04056869269931 listed 1 Nov 2020 Listed
Recalls
-
- Ongoing Z-0999-2026
A potential issue associated with LUMINOS Lotus Max and Luminos dRF Max systems with software version VF11 with bucky wall stand for mobile detectors and without ceiling stand .When switching quickly between organ programs (OGPs) the collimation may be incorrect.
-
- Ongoing Z-1981-2025
- Ongoing Z-1982-2025
A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire.
-
- Ongoing Z-2527-2024
- Ongoing Z-2525-2024
- Ongoing Z-2526-2024
The support arm may unintentionally lower resulting in injury to persons when they are under the display ceiling/wall suspension when positioning the displays
-
- Ongoing Z-1165-2023
- Ongoing Z-1167-2023
- Ongoing Z-1168-2023
Potential risk of collision with the ceiling, wall, or objects which may result in serious injury to staff or patients due to room configuration parameters of the system being set to default values
-
- Ongoing Z-1002-2023
There is potential for the footrest to detach from the patient table during use. Device intended to visualize anatomical structures by converting an Xray pattern into a visible image. The system has medical applications ranging from gastrointestinal examinations to cranial, skeletal, thoracic and lung exposures as well as examinations of the urogenital tract. The unit may also be used in emergency applications, lymphography, endoscopy, myelography, venography, arthrography, interventional radiology, digital angiography, and digital subtraction angiography (DSA). The system may be used on pediatric, adult, and bariatric patients. These devices are not for mammography examinations.
-
- Ongoing Z-1479-2023
Under certain unlikely circumstances during a fluoroscopic examination, the imaging system Fluorospot Compact might sporadically display an incorrect air kerma/air kerma rate related to the patient reference point, according to IEC 60601-2-43. There is no impact on workflow or diagnosis. The error can occur only in fluoroscopy systems with a second (overhead) X-ray tube. Siemens Healthineers became aware of one customer site where this issue was identified during clinical operation.
-
- Ongoing Z-1480-2023
- Ongoing Z-1481-2023
Under certain unlikely circumstances during a fluoroscopic examination, the imaging system Fluorospot Compact might sporadically display an incorrect air kerma/air kerma rate related to the patient reference point, according to IEC 60601-2-43. There is no impact on workflow or diagnosis. The error can occur only in fluoroscopy systems with a second (overhead) X-ray tube.
-
- Terminated Z-0806-2021
After the March 2019 corrective action on the monitor support arm, there is a residual risk of the support arm becoming dislodged in cases when the monitor support arm is used intensely over a long period of time.
-
- Terminated Z-1331-2020
- Terminated Z-1332-2020
- Terminated Z-1333-2020
Siemens became aware of an issue of incorrect use of the bypass key overriding the built-in collision control creating risk of collision with obstacles or persons when the operator uses the override function.
-
- Terminated Z-1337-2020
- Terminated Z-1338-2020
A software bug may lead to one image to be assigned to two different patients, which could potentially affect medical diagnosis.
-
- Terminated Z-2755-2020
- Terminated Z-2756-2020
- Terminated Z-2757-2020
Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control with obstacles or persons .(2) Incorrectly assigned image affecting Ysio Max, Luminos dRF Max and Luminos Agile Max systems with detector MAX Static causing incorrect base for diagnosis
-
- Terminated Z-0985-2019
The swivel arm holding the monitors may become dislodged from the carrying arm.
Timeline
- Recall initiated FDA recalls Z-1165-2023
- Recall initiated FDA recalls Z-1167-2023
- Recall initiated FDA recalls Z-1168-2023
- Recall initiated FDA recalls Z-2527-2024
- Recall initiated FDA recalls Z-2525-2024
- Recall initiated FDA recalls Z-2526-2024
- Recall initiated FDA recalls Z-1981-2025
- Recall initiated FDA recalls Z-1982-2025
- Recall initiated FDA recalls Z-0999-2026
- Registered EUDAMED B-04056869269931
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- LUMINOS Lotus Max
- Generic name
- Stationary general-purpose fluoroscopic x-ray system, digital
- Device name
- MDD_16_II b_ERLN H 127_Fluoro_digital_Lotus
- Model / reference
- 11574100, MDD_16_II b_ERLN H 127_Fluoro_digital_Lotus
- Primary DI / UDI-DI
- 04056869269931
- Basic UDI-DI
- B-04056869269931
- 510(k) Number
- FDA product code
- OWB
- EMDN code
- Z11039009 Fluoroscopy devices
- GMDN term
- Stationary general-purpose fluoroscopic x-ray system, digital
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1650
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under FLUOROSCOPY DEVICES.
- AREX A03 by GENORAY CO., LTD.
- OSCAR 15(Unique FD) 107 by GENORAY CO., LTD.
- ProxiDiagnost N90 1.1 706110 by Philips Medical Systems DMC GmbH
- GARION by Sg Healthcare Co, Ltd.
- ImagingRing r 1 by medPhoton GmbH
- ProxiDiagnost N90 706100 by Philips Medical Systems DMC GmbH
- OrthoScan Mobile DI Mini C-arm 1000-0005 by Ziehm-Orthoscan, Inc.
- Digital Radiography and Fluoroscopy System GMDN Code: 37679 by Beijing Wandong Medical Technology Co., Ltd.
- Smart-C 902-00001 by Turner Imaging Systems, Inc.
- GARION+ by Sg Healthcare Co, Ltd.