reNEW™ Certified Pre-Owned System H-0000-0003
by Accuray Incorporated 2 variants
reNEW Certified Pre-Owned System H-0000-0003 is a linear accelerator system (FDA Class II; FDA product code IYE, Accelerator, Linear, Medical) made by Accuray Incorporated, cleared under FDA 510(k) K121934 on 29 Aug 2012 and listed in FDA GUDID since 24 Jun 2021 (UDI-DI 00811376030351), active as of 22 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00811376030351 | Date24 Jun 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK121934 | Date29 Aug 2012 | StatusActive |
Official records
- AccessGUDID record 00811376030351
- FDA 510(k) database K121934
From the FDA record
- Device description
- reNEW™ Certified Pre-Owned System
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K121934 decided 29 Aug 2012 Active
- FDA GUDID UDI-DI 00811376030351 listed 24 Jun 2021 Listed
Recalls
-
- Terminated Z-0784-2021
"MLC tickle error" may result in the delivered dose to effectively rotate from the planned dose.
-
- Terminated Z-0286-2018
- Terminated Z-0287-2018
- Terminated Z-0288-2018
- Terminated Z-0289-2018
Uncontrolled couch Z-axis movement (descent)
-
- Terminated Z-0507-2015
Accuray has become aware of a potential safety issue related to the TomoTherapy Treatment System caused by a failure to monitor the jaw position after a jaw error occurs. This may result in an incorrect jaw position during treatment, without generating system interruption.
-
- Terminated Z-2239-2014
Accuray is voluntarily recalling TomoTherapy H Series software versions 1.2.0, 1.2.1 and 1.2.2 (Hi-Art 4.2.0, 4.2.1 and 4.2.2). Accuray has identified potential safety issues (anomalies) with these software versions.
-
- Terminated Z-2240-2014
Accuray is voluntarily recalling TomoTherapy H Series software versions 2.0.0 and 2.0.1 (Hi-Art 5.0.0 and 5.0.1). Accuray has identified potential safety issues (anomalies) with these software versions.
Timeline
- Cleared FDA 510(k) K121934
- Recall initiated FDA recalls Z-2240-2014
- Recall initiated FDA recalls Z-2239-2014
- Recall initiated FDA recalls Z-0507-2015
- Recall initiated FDA recalls Z-0286-2018
- Recall initiated FDA recalls Z-0287-2018
- Recall initiated FDA recalls Z-0288-2018
- Recall initiated FDA recalls Z-0289-2018
- Recall initiated FDA recalls Z-0784-2021
- Listed FDA GUDID 00811376030351
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- reNEW™ Certified Pre-Owned System
- Generic name
- Linear accelerator system
- Model / Ref / Catalog
- H-0000-0003
- Primary DI / UDI-DI
- 00811376030351
- 510(k) Number
- FDA product code
- IYE
- GMDN term
- Linear accelerator system
- Device class
- Class II
- Regulation number
- 892.5050
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code IYE (Accelerator, Linear, Medical).
- KLARITY MEDICAL R550-LB2 by Klarity Medical Products, LLC
- BodyFIX System by Medical Intelligence Medizintechnik GmbH
- Multiple by Larson Medical Products, Inc.
- KLARITY MEDICAL R550-U5 by Klarity Medical Products, LLC
- Peacock System by Nomos Corp.
- Orfit Industries 32042 by Orfit Industries NV
- Super Tissue by I.Z.I. Corp.
- XKNIFE-4 by Radionics, Inc.
- Klarity by Larson Products, Inc.