GM85
by Samsung Electronics Co., Ltd.
510(k) K220175Ref GM85
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8806090DGRGM001XK 08806088582412 | Date21 Apr 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK222353 | Date29 Sep 2022 | StatusActive |
| United States | FDA 510(k)SESE 510(k) | NumberK220175 | Date21 Apr 2022 | StatusActive |
| United States | GUDID listing GUDID | Number08806088582412 | Date26 Nov 2016 | StatusListed |
Official records
- EUDAMED public site 8806090DGRGM001XK
- AccessGUDID record 08806088582412
- FDA 510(k) database K222353
- FDA 510(k) database K220175
- FDA 510(k) database K182183
- FDA 510(k) database K181626
- FDA 510(k) database K180543
- FDA 510(k) database K171119
- FDA 510(k) database K162278
Across registries
- EUDAMED Basic UDI-DI 8806090DGRGM001XK registered 21 Apr 2026 Active
- FDA 510(k) K222353 decided 29 Sep 2022 Active
- FDA GUDID UDI-DI 08806088582412 listed 26 Nov 2016 Listed
Recalls
-
- Ongoing Z-0480-2026
The four (4) M5 bolts that secure the Tube Head Unit to the end of the arm may loosen or fracture due to metal fatigue.
-
- Ongoing Z-1056-2024
Mobile x-ray systems moving arm frame welding issue which presents the potential of bodily harm due to fall of the arm.
-
- Ongoing Z-1414-2023
Issue related to the operation of the arm latch within the column that supports the arm, potential bodily harm due to a fall of the arm
-
- Terminated Z-1691-2019
Potential issue related to the operation of the safety latch within the column that supports the arm due to a possibility of potential bodily harm due to a fall of the arm in an unlikely event that the column wire breaks.
Timeline
- Cleared FDA 510(k) K180543
- Cleared FDA 510(k) K181626
- Cleared FDA 510(k) K182183
- Recall initiated FDA recalls Z-1691-2019
- Cleared FDA 510(k) K220175
- Cleared FDA 510(k) K222353
- Recall initiated FDA recalls Z-1414-2023
- Recall initiated FDA recalls Z-1056-2024
- Recall initiated FDA recalls Z-0480-2026
- Registered EUDAMED 8806090DGRGM001XK
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Mobile basic diagnostic x-ray system, digital
- Device name
- Digital Diagnostic Mobile X-ray System
- Model / reference
- GM85
- Primary DI / UDI-DI
- 08806088582412
- Basic UDI-DI
- 8806090DGRGM001XK
- FDA product code
- IZL, MQB
- EMDN code
- Z11031101 Multifunctional systems for direct digital radiology
- GMDN term
- Mobile basic diagnostic x-ray system, digital
- Device class
- Class IIb EUDAMEDClass II 510(k)GUDID
- Regulation
- 21 CFR Part 892.1720 510(k)GUDID892.1680 GUDID
- System or procedure pack
- System which is a device in itself
- EU registration type
- Standard device
- EU market of registration
- Finland
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | 510(k) | GUDID |
|---|---|---|---|
| Device class | Class IIb | Class II | Class II |
Overview
AI-generated summary, 18 Sep 2026
The GM85 is a Mobile X-Ray System (OpenFDA classification: IZL) designed for portable radiographic imaging. It generates X-ray images by transmitting ionizing radiation through a patient’s body, capturing the resulting signals via detectors and converting them into digital data for diagnostic evaluation. The system is configured for versatile radiographic applications, including general radiography and specialized imaging in mobile settings.
The GM85 is supplied as a reusable, non-sterile device intended for use in clinical radiology departments, emergency settings, or mobile imaging units. It features optional configurations, such as a collapsible column type with manual collimation, multiple detector options, and wired/wireless exposure switches. The system operates under FDA 510(k) clearance (K220175, K222353) and EU MDR compliance, with no MRI safety restrictions. Storage and handling follow standard radiographic equipment protocols.
Devices cleared under K220175
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| GM85 | GM85 | 08806088582412 | — | On the market |
| S4335-AWM | S4335-AWM | 08806094458213 | — | On the market |
| S4343-AWM | S4343-AWM | 08806094458220 | — | On the market |
Similar devices in this category
Other devices filed under MULTIFUNCTIONAL SYSTEMS FOR DIRECT DIGITAL RADIOLOGY.
- Cardiovascular Angiography System by Allengers Medical Systems Limited
- D-EVOIII G35 DR-ID 1801 SE E by FUJIFILM CORPORATION
- RSM 2430C Choice by Drtech Corp.
- XERA GR10X-50K by XERA Medical Systems and Technology Ltd.
- RSM 1824C with RConsole1 by DRTECH Corporation
- Direct Digital Radiology System GMDN Code: 37645 by Beijing Wandong Medical Technology Co., Ltd.
- FDR D-EVO Mobile Compo DR-ID 800 IU DV3 E by FUJIFILM CORPORATION
- Medical X-ray Radiography Unit New Oriental 1000UE by Beijing Wandong Medical Technology Co., Ltd.
- Promo Mobile X-Ray System by DRGEM Corporation
- YSIO X.pree 11107464 by Siemens Healthcare GmbH