Optima Coil System OPTI0101CSS10
by Balt USA LLC
Ref OPTI0101CSS10
Optima Coil System OPTI0101CSS10 is a neurovascular embolization coil (EU MDD Class III; FDA Class II; FDA product code HCG, Device, Neurovascular Embolization) made by Balt USA LLC, registered in EUDAMED on 13 Oct 2026 (Basic UDI-DI B-00818053025709), cleared under FDA 510(k) K172390 on 18 Feb 2018 and listed in FDA GUDID since 26 Feb 2020 (UDI-DI 00818053025709), active as of 24 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00818053025709 00818053025709 | Date13 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00818053025709 | Date26 Feb 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK172390 | Date18 Feb 2018 | StatusActive |
Official records
- EUDAMED public site B-00818053025709
- AccessGUDID record 00818053025709
- FDA 510(k) database K172390
From the FDA record
- Device description
- The Optima Coil System is indicated for endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations (AVMs) and arteriovenous fistulae. The Optima Coil System is also indicated for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolization in the peripheral vasculature. The Optima Coil System comprises of implant coil and a pusher assembly. The Optima Coil System is designed fr use with the XCEL Detachment Controller. The Optima coil is detached thermally with the XCEL Detachment Controller.
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00818053025709 registered 13 Oct 2026 Active
- FDA 510(k) K172390 decided 18 Feb 2018 Active
- FDA GUDID UDI-DI 00818053025709 listed 26 Feb 2020 Listed
Recalls
-
- Ongoing Z-1988-2025
Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification.
-
- Ongoing Z-1041-2024
Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher. Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli.
-
- Ongoing Z-0103-2023
Product pouch label does not match up with carton label
-
- Ongoing Z-1680-2022
Products were released to customers prior to the approval and release of a test report authorizing the use of an existing material from an alternate supplier.
Timeline
- Cleared FDA 510(k) K172390
- Listed FDA GUDID 00818053025709
- Recall initiated FDA recalls Z-1680-2022
- Recall initiated FDA recalls Z-0103-2023
- Recall initiated FDA recalls Z-1041-2024
- Recall initiated FDA recalls Z-1988-2025
- Registered EUDAMED B-00818053025709
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Optima Coil System
- Generic name
- Neurovascular embolization coil
- Device name
- Neurovascular embolization device
- Model / reference
- OPTI0101CSS10
- Primary DI / UDI-DI
- 00818053025709
- Basic UDI-DI
- B-00818053025709
- 510(k) Number
- FDA product code
- HCG
- EMDN code
- Z12109001 Detachable coil equipment for brain aneurysms
- GMDN term
- Neurovascular embolization coil
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 882.5950
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Similar devices in this category
Other devices filed under NEUROLOGY AND NEUROSURGERY INSTRUMENTS.
- Connecting Cable CCB000157-00 by Cerenovus, Inc.
- V-Grip Detachment Controller VG900-MDR VG501 by MICROVENTION INC.
- ELECTRO DETACH GENERATOR v4 347-404R by Kaneka Corp.
- Cadwell 1309 by Xi'an Friendship Medical Electronics Co., Ltd.
- Cascade IOMAX Intraoperative Monitor by Cadwell Industries, Inc.
- Friendship Medical 1047 by Xi'an Friendship Medical Electronics Co., Ltd.
- Neurostimulator TWISTER® TC 20-0200 by Dr. Langer Medical GmbH
- EpiMonitor by Empatica EpiMonitor-AND by Empatica S.r.L.
- ISIS 504261 by inomed Medizintechnik GmbH
- Nerve Monitoring Patient Interface NIM4CPB1 by Medtronic Xomed Inc