Paradigm 1.5ML Reservoir, Model 326
510(k) K001828
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK001828 | Date18 Aug 2000 | StatusActive |
Recalls
-
- Terminated Z-1986-2013
Medtronic is recalling certain lots of Medtronic MiniMed Paradigm Reservoirs MMT-326A (1.8mL) and MMT-332A (3.0mL) used with Medtronic Paradigm insulin pumps because they may have increased risk for leaking. A leak in the reservoir may result in delivery of less insulin than intended. In addition, if there is a leaky reservoir and an insulin blockage occurs in the infusion set, the pump may not
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- FRN
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.5725
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
This device is a Pump, Infusion, classified as a Class II medical device under FDA regulations. The Paradigm 1.5ml Reservoir, Model 326, is designed as a reservoir component for insulin infusion pumps, intended to hold and deliver insulin via a connected infusion set. It features a 1.5ml capacity and is engineered to interface with traditional Luer Lock systems, ensuring compatibility with insulin pump systems. The reservoir incorporates a silicone membrane to facilitate insulin flow and maintain system integrity during use.
The Paradigm 1.5ml Reservoir, Model 326 is supplied as a single-use, non-sterile component for use with insulin infusion pumps, specifically the 5 Series Insulin Pumps from Medtronic MiniMed. It is intended for in-home or clinical settings where insulin delivery is required, such as diabetes management. The device is not MRI-safe and must be handled and stored according to manufacturer guidelines to ensure proper functionality and patient safety. Authorized under FDA 510(k) clearance (K001828), it is regulated under 21 CFR 880.5725 and falls under the FRN product code for infusion pumps.
Other devices from Minimed, Inc.
Questions
AI-generated answers, 1 Oct 2026
What is the Paradigm 1.5ml Reservoir, Model 326 used for?
The Paradigm 1.5ml Reservoir, Model 326, is a reservoir component specifically designed for insulin infusion pumps. It holds 1.5ml of insulin and delivers it through a connected infusion set, ensuring precise insulin administration for diabetes management in both home and clinical settings. The reservoir interfaces with traditional Luer Lock systems, making it compatible with the Medtronic MiniMed 5 Series Insulin Pumps.
How is the Paradigm 1.5ml Reservoir, Model 326 supplied and what are its sterility and reuse details?
The Paradigm 1.5ml Reservoir, Model 326, is supplied as a single-use component and is non-sterile. It is intended for one-time use only, which helps maintain patient safety and system integrity. Reuse is not recommended or supported by the manufacturer, as it could compromise the device’s functionality and the accuracy of insulin delivery.
Is this reservoir compatible with other insulin pump models?
The Paradigm 1.5ml Reservoir, Model 326, is specifically designed for compatibility with the Medtronic MiniMed 5 Series Insulin Pumps. While it features a Luer Lock system for general compatibility, it is not intended for use with other pump models unless explicitly stated by the manufacturer. Always verify compatibility with your specific insulin pump system before use.
How should the Paradigm 1.5ml Reservoir, Model 326 be stored?
The Paradigm 1.5ml Reservoir, Model 326 should be stored according to the manufacturer’s guidelines to ensure proper functionality and patient safety. Since it is non-sterile and single-use, it should be kept in a clean, dry place, protected from direct sunlight and extreme temperatures. Avoid storing it in environments where it could be exposed to moisture or contaminants, as this could compromise its integrity before use.
Is the Paradigm 1.5ml Reservoir, Model 326 MRI-safe?
No, the Paradigm 1.5ml Reservoir, Model 326 is not MRI-safe. It should not be used or stored in proximity to MRI machines, as exposure to magnetic fields could potentially damage the device or pose safety risks. Always follow manufacturer instructions regarding safe handling and usage environments.