Skip to content

Sharesource 5CGM01

by Baxter Healthcare Corp 2 variants

Sharesource 5CGM01 is a nephrology information system application software (FDA Class II; FDA product code FKX, System, peritoneal, automatic delivery) made by Baxter Healthcare Corp, listed in FDA GUDID since 1 Dec 2020 (UDI-DI 15413765545723), registry data as of 23 Oct 2026. One FDA recall is linked to it.

Listed FDA GUDID listing, no authorization on record

Valid until

Not applicable

Database listing, no authorization

FDA recalls

1 ongoing

This device is named in the recall

Documents

None

No authorization documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number15413765545723 UDI-DI Date1 Dec 2020ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Sharesource is a web-based connectivity platform that allows authorized users, including nephrologists, clinicians, and nurses in the dialysis center, to remotely view and manage treatment information sent from the Claria APD System.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-0409-2026 FDA Class II initiated 28 Aug 2025 UDI-DI 15413765545723 listed

    Vantive has identified a software defect within the Sharesource Claria software, which may cause a patient s updated prescription program settings to not be properly saved on the actual cycler that the patient is using to perform their therapy. As a result, the clinician may think that the patient is receiving the correct prescribed therapy because of what is erroneously displayed on the clinician's remote Sharesource application, when in fact the cycler that is with the patient is actually delivering an outdated and incorrect therapy.

Timeline

2 dated events

  1. Listed FDA GUDID 15413765545723
  2. Recall initiated FDA recalls Z-0409-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — GUDID listing Listed

Specification

GUDID

Trade name
Sharesource
Generic name
Nephrology information system application software
Model / Ref / Catalog
5CGM01
Primary DI / UDI-DI
15413765545723
FDA product code
FKX
GMDN term
Nephrology information system application software
Device class
Class II
Regulation number
876.5630
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code FKX (System, peritoneal, automatic delivery).

Other devices from Baxter Healthcare Corp

See all devices from Baxter Healthcare Corp →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (12, all answered No)