Sharesource Connectivity Platform 5C9400

by Baxter International Inc. 7 variants

Sharesource Connectivity Platform 5C9400 is a nephrology information system application software (FDA Class II; FDA product code FKX, System, peritoneal, automatic delivery) made by Baxter International Inc., cleared under FDA 510(k) K151525 on 9 Oct 2015 and listed in FDA GUDID since 20 Sep 2020 (UDI-DI 45413765565692), active as of 23 Oct 2026. 8 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K151525

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number45413765565692 UDI-DI Date20 Sep 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK151525 Date9 Oct 2015DecidedStatusActive

Official records

From the FDA record

Device description
Sharesource is a web-based connectivity platform that allows authorized users, including nephrologists, clinicians, and nurses in the dialysis center, to remotely view and manage treatment information sent from the Amia APD System.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K151525 decided 9 Oct 2015 Active
  • FDA GUDID UDI-DI 45413765565692 listed 20 Sep 2020 Listed

Recalls

8 recalls · 1 ongoing · FDA

    • Ongoing Z-0550-2024 FDA Class II initiated 15 Nov 2023

    There is to an increase in complaints related to failure alarms for Wet Cassette Integrity Test occurring on the Amia devices.

  • 2 recalls, same reason

    • Terminated Z-2173-2021 FDA Class II initiated 30 Jun 2021 UDI-DI 45413765565692 listed
    • Terminated Z-2174-2021 FDA Class II initiated 30 Jun 2021

    Baxter Healthcare Corporation has identified that the AMIA Sharesource User Guide that is used with the AMIA Automated PD System cyclers incorrectly describes the function of the UF (Ultrafiltration) Limit setting as the ending criteria of the cyclers Extra Last Drain Mode. In some locations in the guide, it states that the UF volume achieved must exceed the programmed UF Limit before the cycler will end the Extra Last Drain, allowing the patient to end therapy or proceed to their last fill.

  • 2 recalls, same reason

    • Terminated Z-0849-2019 FDA Class II initiated 11 Dec 2018
    • Terminated Z-0850-2019 FDA Class II initiated 11 Dec 2018

    Potential for the software on Automated PD System cyclers which can cause shortened dwell times during a Cycle-Based therapy

    • Terminated Z-2597-2018 FDA Class II initiated 12 Jul 2018

    There were instances where the power cord socket detached from the back of the AMIA cycler when the power cord was unplugged from the socket.

    • Terminated Z-3133-2017 FDA Class II initiated 1 Sep 2017

    The firm received increased customer complaints for Missing Red Line, Patient Slow Flow, Solution Slow Flow, and Inadequate Drain alerts on certain lots of the AMIA Automated Peritoneal Dialysis Set with Cassette.

    • Terminated Z-1565-2016 FDA Class II initiated 16 Feb 2016

    Baxter Healthcare Corporation is sending this communication to inform you of incomplete instructions in the AMIA Automated Peritoneal Dialysis (PO) System Clinician Guide for calculating the total recommended solution therapy volume. Specifically, the instructions do not specify the need for an extra 200 mL of PD solution in order to prime the patient line and for air purge operations. The tot

Timeline

10 dated events

  1. Cleared FDA 510(k) K151525
  2. Recall initiated FDA recalls Z-1565-2016
  3. Recall initiated FDA recalls Z-3133-2017
  4. Recall initiated FDA recalls Z-2597-2018
  5. Recall initiated FDA recalls Z-0849-2019
  6. Recall initiated FDA recalls Z-0850-2019
  7. Listed FDA GUDID 45413765565692
  8. Recall initiated FDA recalls Z-2173-2021
  9. Recall initiated FDA recalls Z-2174-2021
  10. Recall initiated FDA recalls Z-0550-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Sharesource Connectivity Platform
Generic name
Nephrology information system application software
Model / Ref / Catalog
5C9400
Primary DI / UDI-DI
45413765565692
510(k) Number
FDA product code
FKX
GMDN term
Nephrology information system application software
Device class
Class II
Regulation number
876.5630
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code FKX (System, peritoneal, automatic delivery).

Other devices from Baxter International Inc.

See all devices from Baxter International Inc. →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (12, all answered No)