TDI Posterior Array

by GE Healthcare Coils 2 variants

Ref 5012345Model TDI Head Neck/ Posterior Array and 3.0T AA

TDI Posterior Array (5012345) is a MRI system coil (EU MDR Class I; FDA Class II) made by GE Healthcare Coils, registered in EUDAMED on 9 Feb 2024 (Basic UDI-DI 8406821BUG00311GY), cleared under FDA 510(k) K143345 on 10 Jul 2015 and listed in FDA GUDID since 1 Aug 2016 (UDI-DI 00840682108867), active as of 22 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

3 ongoing

Recall on shared 510(k) K143345; other models may be affected

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K143345

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00311GY Basic UDI-DI 00840682108867UDI-DIDate9 Feb 2024RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682108867 UDI-DI Date1 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK143345 Date10 Jul 2015DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00311GY registered 9 Feb 2024 Active
  • FDA 510(k) K143345 decided 10 Jul 2015 Active
  • FDA GUDID UDI-DI 00840682108867 listed 1 Aug 2016 Listed

Recalls

6 recalls · 3 ongoing · FDA

    • Ongoing Z-2460-2024 FDA Class II initiated 14 Jun 2024 on shared 510(k) K143345

    GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.

    • Ongoing Z-0592-2022 FDA Class II initiated 23 Dec 2021 on shared 510(k) K143345

    The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.

    • Ongoing Z-2054-2021 FDA Class II initiated 4 Jun 2021 on shared 510(k) K143345

    GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed patient orientation on the system prior to running the initial 3-Plane Localizer Scan (See Figure 1 for reference to buttons.) Selecting and saving a patient orientation that does not match the patient's actual position may result in incorrectly annotated and/or flipped images.

    • Terminated Z-0134-2022 FDA Class II initiated 26 Aug 2021 on shared 510(k) K143345

    Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images.

    • Terminated Z-0876-2020 FDA Class II initiated 23 Dec 2019 on shared 510(k) K143345

    It was identified that due to a potential installation workflow issue, the MR system date could be set incorrectly. The system's date and time setting are used to populate the DICOM header information on images. This could result is an inaccurate date recorded on the images.

    • Terminated Z-1347-2016 FDA Class II initiated 1 Mar 2016 on shared 510(k) K143345

    Ferrous material in the SIGNA Pioneer Table Control Box (TCB) could cause unexpected attraction to the MR system's high strength magnetic field during servicing activities. This could create a potential risk of serious injury to service personnel who attempt to inappropriately remove the TCB from the magnetic field. There have been no events reported as a result of this issue. Clinical scanni

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K143345
  2. Recall initiated FDA recalls Z-1347-2016
  3. Listed FDA GUDID 00840682108867
  4. Recall initiated FDA recalls Z-0876-2020
  5. Recall initiated FDA recalls Z-2054-2021
  6. Recall initiated FDA recalls Z-0134-2022
  7. Recall initiated FDA recalls Z-0592-2022
  8. Registered EUDAMED 8406821BUG00311GY
  9. Recall initiated FDA recalls Z-2460-2024

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
MRI system coil, radio-frequency
Device name
TDI Head Neck/ Posterior Array and 3.0T AA
Model / reference
TDI Head Neck/ Posterior Array and 3.0T AA EUDAMED
5012345 EUDAMED
TDI POSTERIOR ARRAY GUDID
Primary DI / UDI-DI
00840682108867
Basic UDI-DI
8406821BUG00311GY
510(k) Number
FDA product code
MOS, LHN
EMDN code
Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
GMDN term
MRI system coil, radio-frequency
Device class
Class I EUDAMED
Class II GUDID
Regulation number
892.1000, 892.5050
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
TDI Head Neck/ Posterior Array and 3.0T AA
5012345
GUDID
TDI POSTERIOR ARRAY
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000001664
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.

Other devices from GE Healthcare Coils

See all devices from GE Healthcare Coils →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)