Tempus LS-Manual 01-3020
by Remote Diagnostic Technologies Limited
Tempus LS-Manual 01-3020 is a physiologic-monitoring defibrillation system (FDA Class II; FDA product code LDD, Dc-Defibrillator, Low-Energy, (Including Paddles)) made by Remote Diagnostic Technologies Limited, cleared under FDA 510(k) K200849 on 24 Jul 2020 and listed in FDA GUDID since 6 Aug 2020 (UDI-DI 05060472441959), active as of 23 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number05060472441959 | Date6 Aug 2020 | StatusListed |
| United States | FDA 510(k)SESE | NumberK200849 | Date24 Jul 2020 | StatusActive |
Official records
- AccessGUDID record 05060472441959
- FDA 510(k) database K200849
From the FDA record
- Device description
- Tempus LS-Manual Adult Electrodes
- MRI safety
- MR Unsafe
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K200849 decided 24 Jul 2020 Active
- FDA GUDID UDI-DI 05060472441959 listed 6 Aug 2020 Listed
Recalls
-
- Ongoing Z-0557-2025
Due to incorrect labels applied to devices during servicing. Labels contain the incorrect product name and CAT number.
-
- Ongoing Z-2028-2024
Simultaneous ECG measurements with multiple devices, including a manual defibrillator, on the same patient may cause electrical noise or interference, which may lead to distortions of the ECG signal; distortions may lead to no or ineffective pacing, or no or inappropriate defibrillation pulse.
-
- Ongoing Z-1825-2023
Defibrillator/pacemaker module (DPM) may encounter a problem causing communication from the Mainboard to the DPM to fail, leading to no or ineffective pacing with displayed error message "HW failure DPM".
-
- Terminated Z-0564-2021
A software error was detected within software version 1.3.4 for the Tempus LS device. When exiting pacer back into manual mode the pacer pulse wave may put the ECG calibration out of calibration. This software error may result in a delay in therapy, as the clinician is not provided an ECG waveform on which a shockable rhythm decision can be made. The device is still able to deliver a manual defibrillation shock.
Timeline
- Cleared FDA 510(k) K200849
- Listed FDA GUDID 05060472441959
- Recall initiated FDA recalls Z-0564-2021
- Recall initiated FDA recalls Z-1825-2023
- Recall initiated FDA recalls Z-2028-2024
- Recall initiated FDA recalls Z-0557-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Tempus LS-Manual
- Generic name
- Physiologic-monitoring defibrillation system
- Model / reference
- 01-3020
- Primary DI / UDI-DI
- 05060472441959
- 510(k) Number
- FDA product code
- LDD
- GMDN term
- Physiologic-monitoring defibrillation system
- Device class
- Class II
- Regulation number
- 870.5300
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Similar devices
Other devices filed under FDA product code LDD (Dc-Defibrillator, Low-Energy, (Including Paddles)).
- CARDIOPAC DEFIBRILLATOR 444 by Birtcher Corp.
- ZOLL R SERIES by Zoll Medical Corporation
- CARDIOMED by CARDIO-MEDICAL PRODUCTS, INC.
- MODEL #110 STEALTH-TRODE CHILD DEFIB PADS by Cardiotronics, Inc.
- DISP. GEL EXTERNAL PACING & DEFIBRILLATION ELECT. by Phycon
- ZOLL E SERIES ALS by Zoll Medical Corporation
- THERACARD 400 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- MINIDEF (OR DEFIPORT by Odam
- DISP. ACCESSORY TO EXTERNAL TRANS. CARDIAC PACE. by Big Valley Medical
- 280/4 MINI-DEFIBRILLATOR by Life Science Instrumentation, Inc.
Other devices from Remote Diagnostic Technologies Limited
See all devices from Remote Diagnostic Technologies Limited →