Tempus LS-Manual 01-3023
by Remote Diagnostic Technologies Limited
Tempus LS-Manual 01-3023 is a physiologic-monitoring defibrillation system (FDA Class II; FDA product code LDD, Dc-Defibrillator, Low-Energy, (Including Paddles)) made by Remote Diagnostic Technologies Limited, cleared under FDA 510(k) K200849 on 24 Jul 2020 and listed in FDA GUDID since 6 Aug 2020 (UDI-DI 05060472441973), active as of 23 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number05060472441973 | Date6 Aug 2020 | StatusListed |
| United States | FDA 510(k)SESE | NumberK200849 | Date24 Jul 2020 | StatusActive |
Official records
- AccessGUDID record 05060472441973
- FDA 510(k) database K200849
From the FDA record
- Device description
- Tempus LS-Manual CPR Feedback Sensor
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K200849 decided 24 Jul 2020 Active
- FDA GUDID UDI-DI 05060472441973 listed 6 Aug 2020 Listed
Recalls
-
- Ongoing Z-0557-2025
Due to incorrect labels applied to devices during servicing. Labels contain the incorrect product name and CAT number.
-
- Ongoing Z-2028-2024
Simultaneous ECG measurements with multiple devices, including a manual defibrillator, on the same patient may cause electrical noise or interference, which may lead to distortions of the ECG signal; distortions may lead to no or ineffective pacing, or no or inappropriate defibrillation pulse.
-
- Ongoing Z-1825-2023
Defibrillator/pacemaker module (DPM) may encounter a problem causing communication from the Mainboard to the DPM to fail, leading to no or ineffective pacing with displayed error message "HW failure DPM".
-
- Terminated Z-0564-2021
A software error was detected within software version 1.3.4 for the Tempus LS device. When exiting pacer back into manual mode the pacer pulse wave may put the ECG calibration out of calibration. This software error may result in a delay in therapy, as the clinician is not provided an ECG waveform on which a shockable rhythm decision can be made. The device is still able to deliver a manual defibrillation shock.
Timeline
- Cleared FDA 510(k) K200849
- Listed FDA GUDID 05060472441973
- Recall initiated FDA recalls Z-0564-2021
- Recall initiated FDA recalls Z-1825-2023
- Recall initiated FDA recalls Z-2028-2024
- Recall initiated FDA recalls Z-0557-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Tempus LS-Manual
- Generic name
- Physiologic-monitoring defibrillation system
- Model / reference
- 01-3023
- Primary DI / UDI-DI
- 05060472441973
- 510(k) Number
- FDA product code
- LDD
- GMDN term
- Physiologic-monitoring defibrillation system
- Device class
- Class II
- Regulation number
- 870.5300
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code LDD (Dc-Defibrillator, Low-Energy, (Including Paddles)).
- TEC-8251A DEFIBRILLATOR MONITOR, MODIFICATION by NIHON KOHDEN AMERICA, INC.
- MARQUETTE PEDIATRIC DEFIBRILLATION/PACING PADS by Marquette Electronics, Inc.
- FC-700 DEFIBRILLATOR by FUKUDA DENSHI USA, INC.
- GEL-TAC(R) by Padeco, Inc.
- DEFIGARD M(OR DEFISCOPE M by Odam
- TELEPHONE DEFIBRILLATOR SYSTEM by Medphone Corp.
- MODEL #250 DEFIB CABLE by Cardiotronics, Inc.
- CARDIOPAC DEFIBRILLATOR 444 by Birtcher Corp.
- ZOLL R SERIES by Zoll Medical Corporation
- CARDIOMED by CARDIO-MEDICAL PRODUCTS, INC.
Other devices from Remote Diagnostic Technologies Limited
See all devices from Remote Diagnostic Technologies Limited →