YSIO

by Siemens Medical Solutions USA, Inc.

510(k) K081722

YSIO is a medical device (FDA Class II; FDA product code KPR, System, X-Ray, Stationary) made by Siemens Medical Solutions USA, Inc., cleared under FDA 510(k) K081722 on 22 Aug 2008, active as of 22 Oct 2026. 7 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK081722 Date22 Aug 2008ClearedStatusActive

Official records

From the FDA record

Received by the FDA
18 Jun 2008
FDA decision
22 Aug 2008 (Substantially Equivalent)
FDA review time
65 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K081722 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

11 recalls · 1 ongoing · FDA

    • Ongoing Z-0841-2022 FDA Class II initiated 31 Jan 2022

    Siemens Healthineers has identified a software error in previous software version VB10 for the Ysio fully automated system. The unit may process incorrect internal values for the position of its ceiling tube stand. If the user activates a longitudinal or transversal movement at the time of the error, the system controls may initiate a correction of the tube stand position, resulting in an unintended movement. If the described error occurs, a potential for collision risk for objects or persons in the vicinity of the moving stand exists. This may result in minor to serious injuries to persons.

    • Terminated Z-1501-2020 FDA Class II initiated 10 Feb 2020

    The Ysio system may process incorrect internal values for the position of its ceiling tube stand. If in this situation the user activates longitudinal or transversal stand movement (by using the buttons at the tube head or the remote console), the systems controls may (depending on the values being processed) initiate a correction of the tube stand position, resulting in an unexpected movement.

    • Terminated Z-0299-2019 FDA Class II initiated 6 Aug 2018

    In rare cases of high clinical workload, the steel cables inside the lifting column of the overhead tube, which are designed to take the load, may rapture without triggering the safety lock. This could lead to overloading the safety rope, which is not designed for continuous load and ongoing movement under load. This may lead to mechanical fatigue and cause the arm to drop down unexpectedly during movement in vertical direction and during patient positioning.

    • Terminated Z-2680-2014 FDA Class II initiated 27 Aug 2014

    Siemens discovered that an unlikely error may occur on the Ysio system with fixed detector in the wall stand. This error may result in line artifacts in the image. If these artifacts appear in the region of interest, the examination may need to be repeated.

    • Terminated Z-2292-2014 FDA Class II initiated 7 Jul 2014 on shared 510(k) K081722

    It was discovered that during a RAD examination using Siemens Luminos dRF, Ysio or Uroskop Omnia systems with software version VB10C to VB10F and automatic exposure control, a highly unlikely malfunction can result in longer radiation exposure than required. This may also result in an overexposed image that is not of diagnostic quality. As a result the taken examination needs to be repeated. Thi

    • Terminated Z-1717-2014 FDA Class II initiated 9 May 2014

    Excessive usage of cleaning liquid on Siemens Ysio Systems may cause infiltration of the generator console, which may lead to a short circuit causing an unintended release of radiation.

    • Terminated Z-0374-2014 FDA Class II initiated 3 Sep 2013

    A potential malfunction and hazard to patients exists when using the Ysio, Luminos Agile, Luminos dRF, and Uroskop Omnia systems with software version VC10, which may result in radiation continuing longer than required and overexposed images that are not of diagnostic quality.

    • Terminated Z-1845-2014 FDA Class II initiated 28 Aug 2013

    When using systems operating with software versions VD10A/G during a RAD examination, a malfunction can result in the image appearing very dark, which may prompt unnecessary repetition of the examination.

    • Terminated Z-0016-2014 FDA Class II initiated 6 May 2013 on shared 510(k) K081722

    Siemens has discovered through product monitoring a potential malfunction when using system operating with software versions VB10D, VB10F, VB10C and VB10. During a RAD examination the possibility exists that radiation may continue longer than expected and may result in unnecessary dose applied during an acquisition. Additionally, it is not possible for the user to stop the radiation manually; ho

    • Terminated Z-1159-2012 FDA Not yet classified initiated 15 Feb 2012 on shared 510(k) K081722

    Firm has become aware of unintended behavior when using Ysio, AXIOM dRF, AXIOM Luminos Agile/TF and Uroskop Omnia with RAD Fluoro Uro function using software version VC10A. Due to an error in the image pipeline, images may display dark and not suitable for diagnostic. Due to this software error customers have to repeat x-ray exposure to receive diagnostic images.

    • Terminated Z-2787-2011 FDA Unclassified (pre-2012) initiated 28 Apr 2011 on shared 510(k) K081722

    There is a potential hazard to staff or patients when lowering the table height on the Ysio system. If staff or patients lower extremities are placed underneath the table and the user lowers the table top, it is possible that parts of the table may collide with extremities and cause injuries.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-1159-2012
  2. Recall initiated FDA recalls Z-0016-2014
  3. Recall initiated FDA recalls Z-1845-2014
  4. Recall initiated FDA recalls Z-0374-2014
  5. Recall initiated FDA recalls Z-1717-2014
  6. Recall initiated FDA recalls Z-2292-2014
  7. Recall initiated FDA recalls Z-2680-2014
  8. Recall initiated FDA recalls Z-0299-2019
  9. Recall initiated FDA recalls Z-1501-2020
  10. Recall initiated FDA recalls Z-0841-2022

2 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
KPR
Device class
Class II
Regulation
21 CFR Part 892.1680
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code KPR (System, X-Ray, Stationary).