Z-800 Infusion System
510(k) K130690
Z-800 Infusion System is a medical device (FDA Class II; FDA product code FRN, Pump, Infusion) made by Zyno Medical, LLC, cleared under FDA 510(k) K130690 on 12 Jun 2013, active as of 22 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
9 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK130690 | Date12 Jun 2013 | StatusActive |
Official records
- FDA 510(k) database K130690
From the FDA record
- Received by the FDA
- 14 Mar 2013
- FDA decision
- 12 Jun 2013 (Substantially Equivalent)
- FDA review time
- 90 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-1865-2025
- Ongoing Z-1866-2025
- Ongoing Z-1867-2025
- Ongoing Z-1868-2025
Unreleased software versions were installed on distributed devices without verification or validation.
-
- Ongoing Z-0506-2025
Potential for the battery to deplete over time from self-discharge and internal parasitic leakage current despite being continuously plugged into AC mains.
-
- Ongoing Z-0523-2025
For the Z-800WF pumps, the WiFi software was not compatible with the pump software that had been loaded in accordance with ongoing correction Z-1183-2024.
-
- Ongoing Z-0005-2025
There is a defect in the air-in-line software algorithm.
-
- Ongoing Z-2263-2024
Zyno Medical has found that certain Z800, Z800F, Z800W, and Z800WF pumps have faulty power supply modules that will not provide a charge to the rechargeable battery within the pump. This may lead to the battery having insufficient or no charge available to the pump when it is unplugged from the AC mains power.
-
- Ongoing Z-1183-2024
When utlizing the patient query feature on the Zyno Medical Z-800WF pumps with software version 5.2.05, the alarm volume may inadvertently revert from a higher volume setting to a low one, causing potential delays in therapy and in extreme cases, associated risk of organ failure or death
Timeline
- Cleared FDA 510(k) K130690
- Recall initiated FDA recalls Z-1183-2024
- Recall initiated FDA recalls Z-2263-2024
- Recall initiated FDA recalls Z-0005-2025
- Recall initiated FDA recalls Z-0523-2025
- Recall initiated FDA recalls Z-0506-2025
- Recall initiated FDA recalls Z-1865-2025
- Recall initiated FDA recalls Z-1866-2025
- Recall initiated FDA recalls Z-1867-2025
- Recall initiated FDA recalls Z-1868-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- FRN
- Device class
- Class II
- Regulation
- 21 CFR Part 880.5725
- Advisory committee
- General Hospital
- FDA decision
- SESE Substantially Equivalent
Devices cleared under K130690
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| Z-800 | Z-800 / Z-800 | 00814371020006 | — | On the market |
| Z-800F | Z-800F / Z-800F | 00814371020013 | — | On the market |
| Z-800W | Z-800W / Z-800W | 00814371020020 | — | On the market |
| Z-800WF | Z-800WF / Z-800WF | 00814371020037 | — | On the market |
Similar devices
Other devices filed under FDA product code FRN (Pump, Infusion).
- 3M MODEL 3000 & MODEL 3100 INFUSION PUMP (MODIFICATION) by Minnesota Mining and Mfg. Co.
- DANBY-DCR VOLUMETRIC INFUSION PUMP by Danby Medical, Ltd.
- STREAM-SWITCH MANIFOLD by Intelligent Medicine, Inc.
- Integrated Catch-up Freedom Syringe Driver Infusion System by Repro-Med Systems, Inc. Dba Rms Medical Products
- BASAL/BOLUS INFUSORS by Baxter Healthcare Corp
- AVI MODEL 270CI INFUSION PUMP by 3M Avi, Inc.
- IVAC(R) STAR-FLOW(TM) VOLUMETRIC PUMP - MODEL 580+ by Y
- MODEL 2000 INDULIN INFUSION PUMP by Bd Becton Dickinson Vacutainer Systems Preanalytic
- VEINNOVATIONS INFILTRATION SYSTEM by Veinnovations, LLC
- IMED MODEL PC-4 VOLUMETRIC INFUSION PUMP/CONTROLLE by Imed Corp.