Skip to content

Ziehm Vision RFD

by Ziehm Imaging, Inc.

510(k) K083545

Ziehm Vision RFD is a medical device (FDA Class II; FDA product code OWB, Interventional Fluoroscopic X-Ray System) made by Ziehm Imaging, Inc., cleared under FDA 510(k) K083545 on 15 May 2009, active as of 22 Oct 2026. 2 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK083545 Date15 May 2009ClearedStatusActive

Official records

From the FDA record

Received by the FDA
28 Nov 2008
FDA decision
15 May 2009 (Substantially Equivalent)
FDA review time
168 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K083545 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

3 recalls · FDA

    • Terminated Z-2641-2016 FDA Class II initiated 15 Apr 2016

    Malfunction of the radiation-warning timer and the 3D-specific interval warning. No 5-minute timer dialogs or beeper will occur until the unit is rebooted.

    • Terminated Z-0568-2014 FDA Class II initiated 21 Nov 2013

    Engineering change in 2006 resulted in a minor non-conformity of their devices. Specifically the emergency switch was changed from a standard component to just an option on the devices.

    • Terminated Z-1430-2012 FDA Unclassified (pre-2012) initiated 29 Apr 2011 on shared 510(k) K083545

    On 04/29/2011, Ziehm Imaging, Inc., Orlando, FL recalled the double foot switch, type KF 2 1S/1S-MED-AP, a component used with Ziehm Imaging GmbH Mobile C-arm due to the potential of unintentional continued activation of fluoroscopic X-ray as the foot switch may not become inactive when the pedal is released.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

4 dated events

  1. Cleared FDA 510(k) K083545
  2. Recall initiated FDA recalls Z-1430-2012
  3. Recall initiated FDA recalls Z-0568-2014
  4. Recall initiated FDA recalls Z-2641-2016

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
OWB
Device class
Class II
Regulation
21 CFR Part 892.1650
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code OWB (Interventional Fluoroscopic X-Ray System).

Other devices from Ziehm Imaging, Inc.

See all devices from Ziehm Imaging, Inc. →