Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

Trilliant Surgical LLC

US

Last updated September 17, 2026

Information

Country
US
Address
727 N. Shepherd Dr, Houston, TX, 77007
Website
—
LinkedIn
—
Facebook
—
Email
—
Phone
—
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
3007420745
DUNS Number
—

Catalogue (1635)

Page 8 of 33
DeviceModel / ReferenceRegistriesClassStatus
Arsenal Foot 300-81-005
FDA UDI
Class IIActive
Tiger 201-20-038
FDA UDI
Class IIActive
Tiger 217-55-003
FDA UDI
Class IActive
4.0mm x 20mm Gridlock Ankle Screw 304-40-020
FDA UDI
Class IIActive
3.5mm x 26mm Gridlock Ankle Screw 304-35-026
FDA UDI
Class IIActive
3.0mm Gridlock Screw Overdrill bit 310-31-001
FDA UDI
Class IActive
4.0mm x 56mm Gridlock Ankle Syndesmotic Screw LP 306-41-056
FDA UDI
Class IIActive
Tiger 203-30-148
FDA UDI
Class IIActive
Tiger 202-24-022
FDA UDI
Class IIActive
Stabilization 330-35-016
FDA UDI
Class IActive
Tiger 210-40-002
FDA UDI
Class IActive
Htr 220-12-002
FDA UDI
Class IActive
Tiger 206-70-055
FDA UDI
Class IIActive
Tiger 202-20-014
FDA UDI
Class IIActive
Right Talar Cut Guide Assy, Gen II STAR Ankle 726-0110
FDA UDI
Class IActive
Tiger 200-45-140
FDA UDI
Class IIActive
2.4mm x 18mm Gridlock Screw 301-24-018
FDA UDI
Class IIActive
Arsenal Foot 307-40-018
FDA UDI
Class IIActive
Tiger 213-01-100
FDA UDI
Class IActive
Arsenal Foot 307-27-020
FDA UDI
Class IIActive
Tiger 211-00-007
FDA UDI
Class IActive
Arsenal Foot 308-35-034
FDA UDI
Class IIActive
Arsenal Foot 308-22-026
FDA UDI
Class IIActive
Tiger 200-24-008
FDA UDI
Class IIActive
Tiger 201-20-030
FDA UDI
Class IIActive
Tiger 202-45-045
FDA UDI
Class IIActive
3.0mm Calibrated Drill Bit 510-30-002
FDA UDI
Class IActive
Tiger 201-30-140
FDA UDI
Class IIActive
Tiger 215-00-011
FDA UDI
Class IActive
6 Hole 1/3 Tubular Gridlock Ankle Plate 300-63-001
FDA UDI
Class IIActive
9mm STAR E+ Sliding Core STAR Total Ankle 602-03-009
FDA UDI
Class IIIActive
Tiger 201-30-048
FDA UDI
Class IIActive
Subtalar Tray Shipping Insert 112-00-006
FDA UDI
Class IActive
4.0mm Ankle Variable/Static Angle Drill Guide 320-40-005
FDA UDI
Class IActive
4.0mm x 24mm Gridlock Ankle Locking Screw 305-40-024
FDA UDI
Class IIActive
Arsenal Ankle 340-27-006
FDA UDI
Class IActive
8mm x 8mm Staple System 500-08-001
FDA UDI
Class IIActive
Arsenal Foot 330-01-210
FDA UDI
Class IActive
Arsenal Foot 330-86-001
FDA UDI
Class IActive
Two-Step Hammertoe 204-24-014
FDA UDI
Class IIActive
8mm Twist Subtalar Implant 102-10-008
FDA UDI
Class IIActive
Arsenal Foot 330-24-004
FDA UDI
Class IActive
Syndesmotic Screw Remover 320-40-016
FDA UDI
Class IActive
20mm x 20mm x 20mm Staple 500-20-101
FDA UDI
Class IIActive
Arsenal Foot 308-40-022
FDA UDI
Class IIActive
Tiger 202-45-060
FDA UDI
Class IIActive
10 Hole Contoured VL Gridlock Fibula Plate 300-61-006
FDA UDI
Class IIActive
Tiger 200-45-002
FDA UDI
Class IIActive
4.0mm x 34mm Gridlock Screw 301-40-034
FDA UDI
Class IIActive
Tiger 200-45-024
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (24)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Nov 4, 2019Z-1635-2020—terminated

The firm has identified that parts from the kit, lot: TSL007202, have the potential to contain the incorrect contents of the 8mm HTR Sterile Hammer Toe Reaming Kit. The kit should contain (2) reamers total, (1) Concave Reamer and (1) Convex Reamer; there is the potential that kits from the identified lot may have (2) of the same reamer type as opposed to one (1) of each type.

Oct 10, 2019Z-1892-2020—terminated

Labeling Error; specifically, drill bits from lots # TSL008495A are marked with the lot # of TSL008495. This could lead to parts being misidentified and impact device traceability.

Mar 14, 2019Z-0799-2020—terminated

A screwdriver used to facilitate implant insertion and removal was found to be out of specification for the minor diameter of the drive feature causing the driver to be unable to retain screws as intended.

Jul 19, 2018Z-1608-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1612-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1614-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1610-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1609-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1605-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1611-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1606-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1607-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Jul 19, 2018Z-1613-2020—terminated

Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

Mar 27, 2018Z-2339-2018—terminated

Firm is voluntarily recalling cannulated driver handles (210-00-003 and 210-00-004) that may demonstrate a degradation of function with the adapter collar sticking, and/or not retaining the mating adapter male shaft.

Mar 27, 2018Z-2338-2018—terminated

Firm is voluntarily recalling cannulated driver handles (210-00-003 and 210-00-004) that may demonstrate a degradation of function with the adapter collar sticking, and/or not retaining the mating adapter male shaft.

Dec 8, 2016Z-0960-2017—terminated

Four lots of Tiger Screw Sterilization Tray Base Assemblies were released to the field with a printing error where k-wire description markings indicate diameters of 0.45 and 0.35 instead of 0.045" and 0.035", respectively.

Sep 2, 2016Z-0609-2017—terminated

Screws were identified as having the incorrect part number and lot number marked upon them. The part number incorrectly indicated a length of 115 mm rather than 110 mm. The lot number incorrectly indicated lot number of TSL003765 rather than TSL003721.

Aug 6, 2015Z-2490-2015—terminated

The affected parts subject to the recall are out of specification, resulting in in the loss of the optimal locking screw functionality of the plates. The thread depth of the screw holes is insufficient, potentially limiting the ability to engage and lock with associated mating locking screws.

Jul 31, 2015Z-2738-2015—terminated

Gridlock screw driver bits for the Gridlock Plating System were identified to be out of specification and have the potential for shallow engagement between the driver and the screw, resulting in an increased likelihood of stripping screw heads intraoperatively. Specifically, the minor diameter of the drive feature is above the specification, potentially reducing the engagement between the driver and the screw head.

Jul 20, 2015Z-2452-2015—terminated

The cannulation of the 3.0/4.0 Cannulated Drill Bit inner diamter is too small to allow for the guide wire to pass completely through.

Jul 20, 2015Z-2421-2015—terminated

The cutting efficiency of the Countersinks was out of specification.

Jul 20, 2015Z-2456-2015—terminated

The cannulation of the Concave and Convex Reamer Heads may be too small to allow the Guide Pin to freely pass through.

Jul 20, 2015Z-2464-2015—terminated

Sterilization tray lids for the Tiger and Tiger Headless Cannulated Screw Systems were reported to occasionally be difficult to remove from the sterilization tray.

Apr 14, 2009Z-1438-2010—terminated

Firm received several complaints of field failures, e.g., "broke during surgery" and the firm initiated a design change. A communication to sales staff 04/14/2009 instructed them to recover and reconcile these products from user physicians.