C22I
C22I is a surgical ultrasound imaging transducer (FDA Class II) made by Fujifilm Corporation, cleared under FDA 510(k) K191233 on 9 Aug 2019 (4 earlier submissions) and listed in FDA GUDID since 18 Jul 2021 (UDI-DI 04573596211267), active as of 21 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number04573596211267 | Date18 Jul 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK191233 | Date9 Aug 2019 | StatusActive |
Official records
- AccessGUDID record 04573596211267
- FDA 510(k) database K191233
- FDA 510(k) database K163505
- FDA 510(k) database K160559
- FDA 510(k) database K140443
- FDA 510(k) database K134016
From the FDA record
- Device description
- Probe
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use
Across registries
- FDA 510(k) K191233 decided 9 Aug 2019 Active
- FDA GUDID UDI-DI 04573596211267 listed 18 Jul 2021 Listed
Recalls
-
- Ongoing Z-1884-2024
AC adapters of Noblus can heat up, and cause smoke in the worst case, when an excessive mechanical stress is applied to the socket for power cable (frequent insertion/removal of the power cable).
-
- Ongoing Z-0189-2022
Diagnostic ultrasound system with the specified software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display the measurement results correctly with two cardiology measurement functions: Mitral Regurgitation Flow (MR Flow) Measurement; Mitral Valve (MV) Measurement. In addition there is an error in the instruction manual.
-
- Terminated Z-1341-2020
These 18 probes may have mis-wiring in the inner cables, causing decreased sensitivity and thus resulting in lower peak velocity readings.
-
- Terminated Z-2090-2017
The strength of the arm mounting mechanism was insufficient and had to be redesigned.
Timeline
- Cleared FDA 510(k) K134016
- Cleared FDA 510(k) K140443
- Cleared FDA 510(k) K160559
- Recall initiated FDA recalls Z-2090-2017
- Cleared FDA 510(k) K163505
- Cleared FDA 510(k) K191233
- Recall initiated FDA recalls Z-1341-2020
- Listed FDA GUDID 04573596211267
- Recall initiated FDA recalls Z-0189-2022
- Recall initiated FDA recalls Z-1884-2024
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Surgical ultrasound imaging transducer
- Model / reference
- C22I
- Primary DI / UDI-DI
- 04573596211267
- FDA product code
- IYO, IYN, ITX
- GMDN term
- Surgical ultrasound imaging transducer
- Device class
- Class II
- Regulation number
- 892.1560, 892.1550, 892.1570
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Surgical ultrasound imaging transducer.