C22I

by Fujifilm Corporation

C22I is a surgical ultrasound imaging transducer (FDA Class II) made by Fujifilm Corporation, cleared under FDA 510(k) K191233 on 9 Aug 2019 (4 earlier submissions) and listed in FDA GUDID since 18 Jul 2021 (UDI-DI 04573596211267), active as of 21 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 21 Oct 2026.

Regulatory status

as of registry sync 21 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04573596211267 UDI-DI Date18 Jul 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK191233 Date9 Aug 2019DecidedStatusActive

Official records

From the FDA record

Device description
Probe
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use

From the GUDID record (AccessGUDID), as read on 21 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K191233 decided 9 Aug 2019 Active· +4 more in the status table
  • FDA GUDID UDI-DI 04573596211267 listed 18 Jul 2021 Listed

Recalls

4 recalls · 2 ongoing · FDA

    • Ongoing Z-1884-2024 FDA Class II initiated 11 Apr 2024

    AC adapters of Noblus can heat up, and cause smoke in the worst case, when an excessive mechanical stress is applied to the socket for power cable (frequent insertion/removal of the power cable).

    • Ongoing Z-0189-2022 FDA Class II initiated 14 Oct 2021

    Diagnostic ultrasound system with the specified software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display the measurement results correctly with two cardiology measurement functions: Mitral Regurgitation Flow (MR Flow) Measurement; Mitral Valve (MV) Measurement. In addition there is an error in the instruction manual.

    • Terminated Z-1341-2020 FDA Class II initiated 31 Jan 2020

    These 18 probes may have mis-wiring in the inner cables, causing decreased sensitivity and thus resulting in lower peak velocity readings.

    • Terminated Z-2090-2017 FDA Class II initiated 2 May 2017

    The strength of the arm mounting mechanism was insufficient and had to be redesigned.

Timeline

10 dated events

  1. Cleared FDA 510(k) K134016
  2. Cleared FDA 510(k) K140443
  3. Cleared FDA 510(k) K160559
  4. Recall initiated FDA recalls Z-2090-2017
  5. Cleared FDA 510(k) K163505
  6. Cleared FDA 510(k) K191233
  7. Recall initiated FDA recalls Z-1341-2020
  8. Listed FDA GUDID 04573596211267
  9. Recall initiated FDA recalls Z-0189-2022
  10. Recall initiated FDA recalls Z-1884-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Generic name
Surgical ultrasound imaging transducer
Model / reference
C22I
Primary DI / UDI-DI
04573596211267
FDA product code
IYO, IYN, ITX
GMDN term
Surgical ultrasound imaging transducer
Device class
Class II
Regulation number
892.1560, 892.1550, 892.1570
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Surgical ultrasound imaging transducer.

Other devices from Fujifilm Corporation

See all devices from Fujifilm Corporation →

Properties

  • Sterilise before use
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (11, all answered No)