Skip to content

C22T

by Fujifilm Corporation

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 9 Nov 2026.

Regulatory status

as of registry sync 9 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04573596211298 UDI-DI Date18 Jul 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK191233 Date9 Aug 2019DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K191233 decided 9 Aug 2019 Active· +4 more in the status table
  • FDA GUDID UDI-DI 04573596211298 listed 18 Jul 2021 Listed

Recalls

4 recalls · 2 ongoing · FDA

    • Ongoing Z-1884-2024 FDA Class II initiated 11 Apr 2024

    AC adapters of Noblus can heat up, and cause smoke in the worst case, when an excessive mechanical stress is applied to the socket for power cable (frequent insertion/removal of the power cable).

    • Ongoing Z-0189-2022 FDA Class II initiated 14 Oct 2021

    Diagnostic ultrasound system with the specified software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display the measurement results correctly with two cardiology measurement functions: Mitral Regurgitation Flow (MR Flow) Measurement; Mitral Valve (MV) Measurement. In addition there is an error in the instruction manual.

    • Terminated Z-1341-2020 FDA Class II initiated 31 Jan 2020

    These 18 probes may have mis-wiring in the inner cables, causing decreased sensitivity and thus resulting in lower peak velocity readings.

    • Terminated Z-2090-2017 FDA Class II initiated 2 May 2017

    The strength of the arm mounting mechanism was insufficient and had to be redesigned.

Timeline

10 dated events

  1. Cleared FDA 510(k) K134016
  2. Cleared FDA 510(k) K140443
  3. Cleared FDA 510(k) K160559
  4. Recall initiated FDA recalls Z-2090-2017
  5. Cleared FDA 510(k) K163505
  6. Cleared FDA 510(k) K191233
  7. Recall initiated FDA recalls Z-1341-2020
  8. Listed FDA GUDID 04573596211298
  9. Recall initiated FDA recalls Z-0189-2022
  10. Recall initiated FDA recalls Z-1884-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Generic name
Surgical ultrasound imaging transducer
Model / reference
C22T
Primary DI / UDI-DI
04573596211298
FDA product code
IYO, IYN, ITX
GMDN term
Surgical ultrasound imaging transducer
Device class
Class II
Regulation number
892.1560, 892.1550, 892.1570
GUDID distribution status
In Commercial Distribution

Overview

AI-generated summary, 9 Nov 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The C22T is a system, imaging, pulsed echo, ultrasonic. This surgical ultrasound imaging transducer is a probe. It must be sterilized before use with liquid chemical, peracetic acid, hydrogen peroxide, ethylene oxide, or high-level disinfectant. The device is stored at temperatures between -10 and 50 Degrees Celsius, 10 to 90 percent relative humidity, and 70 to 106 KiloPascal atmospheric pressure.

The device received 510(k) clearance under submission numbers K134016, K140443, K160559, K163505, and K191233. It is a Class II device. The product codes are IYO, IYN, and ITX. These correspond to regulation numbers 892.1560, 892.1550, and 892.1570.

Similar devices in this category

Other devices filed under Surgical ultrasound imaging transducer.

Other devices from Fujifilm Corporation

See all devices from Fujifilm Corporation →

Questions

AI-generated answers, 9 Nov 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the C22T?

    It is recorded under the GMDN device type "Surgical ultrasound imaging transducer", which GMDN defines as "A hand-held ultrasound imaging transducer assembly designed to be positioned within a surgical site for localized intraoperative imaging applications". FDA lists it under the product name "System, Imaging, Pulsed Echo, Ultrasonic". It is recorded as Class II.

  • What are the product code and regulation of the C22T?

    FDA records the C22T under product code IYO and regulation number 892.1560.

  • Who makes the C22T?

    FUJIFILM CORPORATION is the manufacturer on record for the C22T.

Properties

  • Sterilise before use
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (11, all answered No)