Easy-Lock 5C4136
Easy-Lock 5C4136 is a peritoneal dialysis system tubing set (FDA Class II; FDA product code FKX, System, peritoneal, automatic delivery) made by Baxter Healthcare Corp, cleared under FDA 510(k) K923065 on 4 Mar 1994 and listed in FDA GUDID since 14 Nov 2018 (UDI-DI 00085412050829), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00085412050829 | Date14 Nov 2018 | StatusListed |
| United States | FDA 510(k)SESE | NumberK923065 | Date4 Mar 1994 | StatusActive |
Official records
- AccessGUDID record 00085412050829
- FDA 510(k) database K923065
From the FDA record
- Device description
- This adapter consists of a spike connector, approx. 10.15 cm (4 inch) long, 3.81 mm (0.150 inch) ID tubing and a flanged Easy-Lock Connector. This device is indicated for the personal cycler peritoneal dialysis system used for automatic control of dialysate solution exchanges in the treatment of renal failure patients undergoing peritoneal dialysis.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K923065 decided 4 Mar 1994 Active
- FDA GUDID UDI-DI 00085412050829 listed 14 Nov 2018 Listed
Recalls
-
- Terminated Z-2132-2012
Baxter discovered that a Baxter technical service representative was providing incorrect instructions for inspection of solution bags for a blocked frangible prior to connection to the Automated PD Set with Cassette.
-
- Terminated Z-0946-2008
Unrecorded Infusion; If the system is powered down or a power failure occurs during a fill cycle, the HomeChoice system may not record the last 1-4 pump strokes infused into the patient when the power is restored. This situation may create a potential unrecorded delivery of approximately 15-60 mL of fluid being infused into the patient.
-
- Terminated Z-1018-05
The screws that secure the Power Entry Module (PEM) to the base of the HomeChoice device are not reliably grounded to the device's ground system, posing an electric shock hazard.
-
- Terminated Z-1012-04
A software defect could result in a patient experiencing an overfill with software versions 8.5 and higher. The possibility of an overfill can occur when the Initial Drain Alarm Volume is set to OFF and a change to the volume is made at the Verify I-DRAIN:XXXXML prompt.
Timeline
- Cleared FDA 510(k) K923065
- Recall initiated FDA recalls Z-1012-04
- Recall initiated FDA recalls Z-1018-05
- Recall initiated FDA recalls Z-0946-2008
- Recall initiated FDA recalls Z-2132-2012
- Listed FDA GUDID 00085412050829
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Easy-Lock
- Generic name
- Peritoneal dialysis system tubing set
- Model / Ref / Catalog
- 5C4136
- Primary DI / UDI-DI
- 00085412050829
- 510(k) Number
- FDA product code
- FKX
- GMDN term
- Peritoneal dialysis system tubing set
- Device class
- Class II
- Regulation number
- 876.5630
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code FKX (System, peritoneal, automatic delivery).
- RINSE BLOCK ASSEM, D-W PERI. DIALYSIS by Quinton, Inc.
- CAPD CATHETER ADAPTER by American Mcgaw
- Digital Dialysis Clinic - Intelligent Dialysis Assistant (IDA) with Medical Supervision Portal and IDA Smartphone App by Iren-Medical, Ltd.
- DELMED 80/2 DIALYSIS SYSTEM W/LAST BAG OPTION by Delmed, Inc.
- CloudCath Peritoneal Dialysis Drain Set Monitoring System by Cloudcath
- CAPD - CATHETER ADAPTER by American Mcgaw
- Fresenius Liberty Select Cycler by Fresenius Medical Care Renal Therapies Group, LLC
- IMPRA PERITONEAL CATHETER by Impra, Inc.
- AUTOMATIC PERITONEAL DIALYSIS CYCLER SYSTEM by Travenol Laboratories, S.A.
- INPERSOL-CAPD ADMINIS. SET TYPE DP by Abbott Laboratories