Effluent Sample Bag 5C4476
Effluent Sample Bag 5C4476 is a peritoneal dialysis system tubing set (FDA Class II; FDA product code FKX, System, Peritoneal, Automatic Delivery) made by Baxter International Inc., cleared under FDA 510(k) K923065 on 4 Mar 1994 and listed in FDA GUDID since 24 Sep 2015 (UDI-DI 00085412007717), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00085412007717 | Date24 Sep 2015 | StatusListed |
| United States | FDA 510(k)SESE | NumberK923065 | Date4 Mar 1994 | StatusActive |
Official records
- AccessGUDID record 00085412007717
- FDA 510(k) database K923065
From the FDA record
- Device description
- This bag is intended to collect sample drainage of peritoneal dialysis effluent from Baxter Peritoneal Dialysis Tubing Sets and is intended for use with Luer connector products.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K923065 decided 4 Mar 1994 Active
- FDA GUDID UDI-DI 00085412007717 listed 24 Sep 2015 Listed
Recalls
-
- Terminated Z-2132-2012
Baxter discovered that a Baxter technical service representative was providing incorrect instructions for inspection of solution bags for a blocked frangible prior to connection to the Automated PD Set with Cassette.
-
- Terminated Z-0946-2008
Unrecorded Infusion; If the system is powered down or a power failure occurs during a fill cycle, the HomeChoice system may not record the last 1-4 pump strokes infused into the patient when the power is restored. This situation may create a potential unrecorded delivery of approximately 15-60 mL of fluid being infused into the patient.
-
- Terminated Z-1018-05
The screws that secure the Power Entry Module (PEM) to the base of the HomeChoice device are not reliably grounded to the device's ground system, posing an electric shock hazard.
-
- Terminated Z-1012-04
A software defect could result in a patient experiencing an overfill with software versions 8.5 and higher. The possibility of an overfill can occur when the Initial Drain Alarm Volume is set to OFF and a change to the volume is made at the Verify I-DRAIN:XXXXML prompt.
Timeline
- Cleared FDA 510(k) K923065
- Recall initiated FDA recalls Z-1012-04
- Recall initiated FDA recalls Z-1018-05
- Recall initiated FDA recalls Z-0946-2008
- Recall initiated FDA recalls Z-2132-2012
- Listed FDA GUDID 00085412007717
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Effluent Sample Bag
- Generic name
- Peritoneal dialysis system tubing set
- Model / Ref / Catalog
- 5C4476
- Primary DI / UDI-DI
- 00085412007717
- 510(k) Number
- FDA product code
- FKX
- GMDN term
- Peritoneal dialysis system tubing set
- Device class
- Class II
- Regulation number
- 876.5630
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code FKX (SYSTEM, PERITONEAL, AUTOMATIC DELIVERY).
- FRSENIUS PD IQCARD CYCLER by Fresenius Medical Care North America
- CCPD CYCLER SET W/5 PRONGED SAFE LOCK by AMERICAN MEDICAL PRODUCTS LLC
- NON-STERILE PERITONEAL ACCESS CATHET- by Evermed, Inc.
- INPERSOL PERITONEAL DIALSIS CYCLER SET by Abbott Laboratories
- VOYAGER PERITONEAL DIALYSIS SYSTEM by DEKA RESEARCH & DEVELOPMENT CORP.
- AUTOMATIC PERITONEAL DIALYSIS CYCLER by Travenol Laboratories, S.A.
- Fresenius Liberty Select Cycler by Fresenius Medical Care Renal Therapies Group, LLC
- CCPD CYCLER SET W/5 PRONGED CONNECTOR by AMERICAN MEDICAL PRODUCTS LLC
- SELECTRA AND TUBING SETS by Medionics International, Ltd.
- Byonyks X-1 APD Cycler; Byonyks Automated PD Set DS-1 by Byonyks Pvt, Ltd.