Skip to content

HL 20 Complete Holder 200mm Arm

by Maquet Cardiopulmonary AG

HL 20 Complete Holder 200mm Arm (701045168) is a cardiopulmonary bypass system (FDA Class II; FDA product code DTQ, Console, Heart-Lung Machine, Cardiopulmonary Bypass) made by Maquet Cardiopulmonary AG, cleared under FDA 510(k) K943803 on 30 Jan 1996 and listed in FDA GUDID since 30 Sep 2021 (UDI-DI 04037691457659), active as of 23 Oct 2026. 5 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

5 closed

Documents

510(k) K943803

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04037691457659 UDI-DI Date30 Sep 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK943803 Date30 Jan 1996DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K943803 decided 30 Jan 1996 Active
  • FDA GUDID UDI-DI 04037691457659 listed 30 Sep 2021 Listed

Recalls

5 recalls · FDA

    • Terminated Z-3057-2011 FDA Unclassified (pre-2012) initiated 20 Jun 2011

    HL 20 Consoles for 4-pump and 5-pump configuration can malfunction if an excessive amount of liquid is used causing circuit board malfunction.

    • Terminated Z-3084-2011 FDA Unclassified (pre-2012) initiated 20 Jun 2011

    Maquet HL 20 Twin Pump Modules may unintentionally increase speeds for a 1.5-2 second period of time before returning to its original speed.

    • Terminated Z-1394-2011 FDA Unclassified (pre-2012) initiated 28 Sep 2010

    A wrong ball bearing was installed in the pump heads of product. This may make the pump head wear out and cease function.

    • Terminated Z-0159-2007 FDA Unclassified (pre-2012) initiated 3 Oct 2006

    The HL-20's pump head on the roller pump has four pairs of tube guide rolls that keep the tube in place in the raceway and roll along the inserted tube as the pump head turns. If dirt and other particles accumulate in the tube guide rolls, they cannot roll smoothly and finally they can get stuck.

    • Terminated Z-0158-2007 FDA Unclassified (pre-2012) initiated 1 Sep 2006

    The hand crank necessary for the emergency manual operation of the pump is too wide diametrically to fit into the holes which they were designed to fill.

Timeline

7 dated events

  1. Cleared FDA 510(k) K943803
  2. Recall initiated FDA recalls Z-0158-2007
  3. Recall initiated FDA recalls Z-0159-2007
  4. Recall initiated FDA recalls Z-1394-2011
  5. Recall initiated FDA recalls Z-3057-2011
  6. Recall initiated FDA recalls Z-3084-2011
  7. Listed FDA GUDID 04037691457659

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Hl 20
Generic name
Cardiopulmonary bypass system, roller type
Model / Ref / Catalog
Complete Holder 200mm Arm, 701045168
Primary DI / UDI-DI
04037691457659
510(k) Number
FDA product code
DTQ
GMDN term
Cardiopulmonary bypass system, roller type
Device class
Class II
Regulation number
870.4220
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code DTQ (Console, Heart-Lung Machine, Cardiopulmonary Bypass).

Other devices from Maquet Cardiopulmonary AG

See all devices from Maquet Cardiopulmonary AG →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (12, all answered No)