Skip to content

Interlink™ Injection Site

by Baxter Healthcare Corp 2 variants

510(k) K925126

Interlink Injection Site is a medical device (FDA Class II; FDA product code FPA, Set, Administration, Intravascular) made by Baxter Healthcare Corp, cleared under FDA 510(k) K925126 on 18 Jun 1993, active as of 22 Oct 2026. 24 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

26 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK925126 Date18 Jun 1993ClearedStatusActive

Official records

From the FDA record

Received by the FDA
13 Oct 1992
FDA decision
18 Jun 1993 (Substantially Equivalent)
FDA review time
248 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K925126 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

26 recalls · FDA

    • Terminated Z-1269-2013 FDA Class II initiated 28 Mar 2013

    Customers have reported that when separating an individual package from its attached grouping, the adjacent package has opened, compromising its sterile barrier properties.

    • Terminated Z-0471-2012 FDA Unclassified (pre-2012) initiated 6 Dec 2011

    During production of the IV sets, solvent was inadvertently applied to the locking collar of the male luer connector, which may have damaged the component, preventing proper engagement of the locking collar to secure a connection.

    • Terminated Z-2837-2011 FDA Unclassified (pre-2012) initiated 6 Jul 2011

    Some of the individual extension set packages were improperly sealed, compromising the sterility of the product.

  • 11 recalls, same reason

    • Terminated Z-0629-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0630-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0634-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0637-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0638-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0640-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0641-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0644-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0648-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-0652-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005
    • Terminated Z-1424-05 FDA Unclassified (pre-2012) initiated 3 Aug 2005

    The extension sets contain microbore female luers that may crack during use, resulting in leakage of medication or incomplete delivery of medication.

  • 2 recalls, same reason

    • Terminated Z-1099-05 FDA Unclassified (pre-2012) initiated 6 Jul 2005
    • Terminated Z-1102-05 FDA Unclassified (pre-2012) initiated 6 Jul 2005

    Leaks and disconnection between the bifurcated Y-site and the set tubing may occur and result in underdelivery of medication, blood loss, and a breach of the sterile fluid pathway.

  • 3 recalls, same reason

    • Terminated Z-1151-03 FDA Unclassified (pre-2012) initiated 16 Jul 2003
    • Terminated Z-1154-03 FDA Unclassified (pre-2012) initiated 16 Jul 2003
    • Terminated Z-1165-03 FDA Unclassified (pre-2012) initiated 16 Jul 2003 on shared 510(k) K925126

    There are possible pinholes or perforations in the set tubing, caused by damage that occurred during the packaging process.

    • Terminated Z-0450-03 FDA Unclassified (pre-2012) initiated 18 Dec 2002 on shared 510(k) K925126

    Leakage may occur at the inlet port

  • 6 recalls, same reason

    • Terminated Z-0505-03 FDA Unclassified (pre-2012) initiated 17 Oct 2002
    • Terminated Z-0507-03 FDA Unclassified (pre-2012) initiated 17 Oct 2002
    • Terminated Z-0509-03 FDA Unclassified (pre-2012) initiated 17 Oct 2002
    • Terminated Z-0517-03 FDA Unclassified (pre-2012) initiated 17 Oct 2002
    • Terminated Z-0518-03 FDA Unclassified (pre-2012) initiated 17 Oct 2002
    • Terminated Z-0522-03 FDA Unclassified (pre-2012) initiated 17 Oct 2002

    The I.V. filter sets contain a 1.2 micron filter instead of the labeled 0.22 micron filter.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

27 dated events

  1. Recall initiated FDA recalls Z-0637-06
  2. Recall initiated FDA recalls Z-0638-06
  3. Recall initiated FDA recalls Z-0640-06
  4. Recall initiated FDA recalls Z-0641-06
  5. Recall initiated FDA recalls Z-0644-06
  6. Recall initiated FDA recalls Z-0648-06
  7. Recall initiated FDA recalls Z-0652-06
  8. Recall initiated FDA recalls Z-2837-2011
  9. Recall initiated FDA recalls Z-0471-2012
  10. Recall initiated FDA recalls Z-1269-2013

17 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Interlink(Tm) Injection Site
510(k) Number
FDA product code
FPA
Device class
Class II
Regulation
21 CFR Part 880.5440
Advisory committee
General Hospital
FDA decision
SESE Substantially Equivalent

Devices cleared under K925126

11 devices · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K925126
UDI-DISize and differences
INTERLINK 1C8454
Baxter Healthcare Corp
1C8454 / 1C845400085412014135 —On the market
INTERLINK 2C6606
Baxter Healthcare Corp
2C6606 / 2C660600085412003955 —On the market
INTERLINK 2C6612
BAXTER INTERNATIONAL INC.
2C6612 / 2C661200085412003962 —On the market
INTERLINK 2C6631
Baxter Healthcare Corp
2C6631 / 2C663100085412002361 —On the market
INTERLINK 2N3371
Baxter Healthcare Corp
2N3371 / 2N337100085412004877 —On the market
INTERLINK 2N3374
BAXTER INTERNATIONAL INC.
2N3374 / 2N337400085412004907 —On the market
INTERLINK 2N3375
BAXTER INTERNATIONAL INC.
2N3375 / 2N337500085412004914 —On the market
INTERLINK 2N3376
Baxter Healthcare Corp
2N3376 / 2N337600085412004921 —On the market
INTERLINK 2N3378
BAXTER INTERNATIONAL INC.
2N3378 / 2N337800085412004938 —On the market
INTERLINK 2N3379
Baxter Healthcare Corp
2N3379 / 2N337900085412004945 —On the market
INTERLINK 2N3399
Baxter Healthcare Corp
2N3399 / 2N339900085412004983 —On the market

Similar devices

Other devices filed under FDA product code FPA (Set, Administration, Intravascular).

Other devices from Baxter Healthcare Corp

See all devices from Baxter Healthcare Corp →