Skip to content

MX8000 V5.0 CT System

by Philips Medical Systems (Cleveland), Inc.

510(k) K010817

MX8000 V5.0 CT System is a medical device (FDA Class II; FDA product code JAK, System, X-Ray, Tomography, Computed) made by Philips Medical Systems (Cleveland), Inc., cleared under FDA 510(k) K010817 on 15 Jun 2001, active as of 22 Oct 2026. 9 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK010817 Date15 Jun 2001ClearedStatusActive

Official records

From the FDA record

Received by the FDA
19 Mar 2001
FDA decision
15 Jun 2001 (Substantially Equivalent)
FDA review time
88 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K010817 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

12 recalls · 1 ongoing · FDA

    • Ongoing Z-1979-2021 FDA Class II initiated 1 May 2021

    Significant wear of the Monitor Bracket Assembly shaft goes unrecognized could potentially lead to the Monitor Bracket Assembly detaching from the Suspension Arm and result in potential hazard for the monitor to fall while remaining attached to the cables resulting in patient, operator, bystander, or service person to serious injury.

    • Terminated Z-1647-2015 FDA Class II initiated 16 Mar 2015

    The firm was informed that while raising the patient couch on the system to perform an exam, the couch unexpectedly descended to the lowest point without being commanded to do so.

    • Terminated Z-1722-2014 FDA Class II initiated 1 Apr 2014

    A customer reported that the table top had become free floating. A Field Service Engineer (FSE) confirmed that the service latch had become disengaged.

    • Terminated Z-0945-2013 FDA Class II initiated 20 Dec 2012

    Philips Healthcare received reports from the field stating the patient table on a system had an unexpected downward movement while a patient was on the table. Philips has determined the cause was a malfunction of the vertical brake.

    • Terminated Z-2914-2011 FDA Unclassified (pre-2012) initiated 3 Jun 2011 on shared 510(k) K010817

    Philips Medical Systems decided to conduct a recall/field correction of the patient support vertical brake hub component in all of their CT MX8000 Dual v. Exp Computed Tomography X-Ray System scanners due to a component defect which could cause an unexpected downward motion of the table (couch) while the patient is on the table. This event could occur because the short key connecting the vertical

    • Terminated Z-0597-2009 FDA Unclassified (pre-2012) initiated 23 Sep 2008 on shared 510(k) K010817

    The product is being recalled because the patient support may travel downwards without being commanded to move.

    • Terminated Z-0014-2007 FDA Unclassified (pre-2012) initiated 6 Nov 2006 on shared 510(k) K010817

    A potential anomaly was identified on the CT subsytem, which could result in the radiation dose being different than the calculated dose reported to the operator.

    • Terminated Z-2709-2014 FDA Class II initiated 27 Dec 2005

    The system has a gap that can appear between the upper and lower tilt stand covers. The fingers may be squeezed if a person was to place them in this region while the gantry was tilting from an angle to zero tilt angle.

  • 3 recalls, same reason

    • Terminated Z-1412-05 FDA Unclassified (pre-2012) initiated 11 Mar 2005
    • Terminated Z-1414-05 FDA Unclassified (pre-2012) initiated 11 Mar 2005
    • Terminated Z-1410-05 FDA Unclassified (pre-2012) initiated 11 Mar 2005

    When two product applications called Flip and Secondary Capture are used together, it is possible for image orientation labels to be incorrect.

    • Terminated Z-0836-03 FDA Unclassified (pre-2012) initiated 2 Apr 2003

    Patient images may be incorrectly stored in the archive directory of a different patient.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

13 dated events

  1. Recall initiated FDA recalls Z-1414-05
  2. Recall initiated FDA recalls Z-1410-05
  3. Recall initiated FDA recalls Z-2709-2014
  4. Recall initiated FDA recalls Z-0014-2007
  5. Recall initiated FDA recalls Z-0597-2009
  6. Recall initiated FDA recalls Z-2914-2011
  7. Recall initiated FDA recalls Z-0945-2013
  8. Recall initiated FDA recalls Z-1722-2014
  9. Recall initiated FDA recalls Z-1647-2015
  10. Recall initiated FDA recalls Z-1979-2021

3 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
JAK
Device class
Class II
Regulation
21 CFR Part 892.1750
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code JAK (System, X-Ray, Tomography, Computed).

Other devices from Philips Medical Systems (Cleveland), Inc.

See all devices from Philips Medical Systems (Cleveland), Inc. →