9733482
9733482 is a stereotactic radiosurgical invasive head frame (FDA Class II; FDA product code LNH, System, nuclear magnetic resonance imaging) made by Medtronic Navigation Inc., cleared under FDA 510(k) K032541 on 12 Sep 2003 and listed in FDA GUDID since 27 May 2016 (UDI-DI 00613994316301), active as of 8 Nov 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00613994316301 | Date27 May 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK032541 | Date12 Sep 2003 | StatusActive |
Official records
- AccessGUDID record 00613994316301
- FDA 510(k) database K032541
From the FDA record
- Device description
- PIN 9733482 INTEGRATED SKULL PIN, 49mm
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K032541 decided 12 Sep 2003 Active
- FDA GUDID UDI-DI 00613994316301 listed 27 May 2016 Listed
Recalls
-
- Terminated Z-2129-2016
Medtronic Navigation is recalling certain components of the PoleStar system (N20 / N30) because of misplaced ground pins which may cause electrical shock to the user.
-
- Terminated Z-2240-2010
Electronic box on headstrap may overheat, causing burn to patient.
Timeline
- Cleared FDA 510(k) K032541
- Recall initiated FDA recalls Z-2240-2010
- Listed FDA GUDID 00613994316301
- Recall initiated FDA recalls Z-2129-2016
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Stereotactic radiosurgical invasive head frame
- Model / reference
- 9733482
- Primary DI / UDI-DI
- 00613994316301
- 510(k) Number
- FDA product code
- LNH
- GMDN term
- Stereotactic radiosurgical invasive head frame
- Device class
- Class II
- Regulation number
- 892.1000
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Length — 49.0 Millimeter
Similar devices
Other devices filed under FDA product code LNH (System, nuclear magnetic resonance imaging).
- QPLAQUE MR by Medis Medical Imaging Systems bv
- OPTIMA MR 430S by GE Medical Systems, LLC
- Digital Expert Access with Remote Scanning by GE Healthcare
- MAGNETOM C! MR SYSTEM by Siemens Medi Cal Solutions, Inc.
- MultiBand SENSE by Philips Medical Systems Nederland B.V.
- uMR 560 by Shanghai United Imaging Healthcare Co., Ltd.
- Stage by Spintech, Inc.
- A BREAST COIL FOR THE GYREX 2T-DIX by Elscint, Inc.
- VISTA HP/HPQ SYSTEM by Philips Medical Systems (Cleveland), Inc.
- MAGNETIC RESONANCE DIAGNOSTIC ACCESSORY by General Electric Co.