Vanguard® Instrument 32-486254
Ref 32-486254
Active
Valid until
Not listed
FDA recalls
None ongoingDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00887868494727 00887868494727 | Date31 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868494727 | Date7 Jul 2022 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Terminated Z-0723-2021
Incorrect bolt -tibial bolts in package instead of femoral bolts may delay procedure
-
- Terminated Z-3249-2018
- Terminated Z-3250-2018
The implant only has one bolt in the sterile package but it should have had two.
-
- Terminated Z-0003-2017
The drill bit used to drill the hex pre-drilled hole in the screw head of the Tibial Augment Bolts included in the Vanguard 360 Revision Knee System was larger than allowable per the process specification. As a result, the hex geometry can still be visible, but there are radial cuts into the hex flat. Therefore, when the bolt is inserted into the augment, the screwdriver is unable to catch on the hex geometry, or the screwdriver strips the remaining hex geometry, and the bolt is unable to be fully tightened. The bolt stripping or the bolt not being fully tightened will be noticed by the surgeon intraoperatively when he or she is unable to screw the augment bolts into the augment. This possible event can result in an intraoperative delay resulting in increased time under anesthesia.
-
- Terminated Z-2242-2014
The Vanguard 360 Femoral Boss Reamers were manufactured oversized to the print. The instrument may not fit into the mating component.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Vanguard® Instrument
- Generic name
- Orthopaedic prosthesis implantation positioning instrument, reusable
- Device name
- Vanguard Bone Nail 1_8
- Model / Ref / Catalog
- 32-486254
- Primary DI / UDI-DI
- 00887868494727
- Basic UDI-DI
- B-00887868494727
- 510(k) Number
- FDA product code
- JWH, MBV
- EMDN code
- L090999 Orthopaedic surgery cutting instruments, reusable - other
- GMDN term
- Orthopaedic prosthesis implantation positioning instrument, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 888.3560
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Other devices from Biomet Orthopedics, Inc.
Properties
Other properties (21)
- Supplied sterile: No
- Single use: No
- Implantable: No
- Contains latex: No
- Reprocessed single-use device: No
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No
- Incorporates a substance derived from human blood or plasma: No
- Contains human tissues or cells: No
- Contains animal tissues or cells: No
- Contains endocrine-disrupting substances: No
- Administering medicine: No
- Measuring function: No
- Incorporates a medicinal substance: No
- Over-the-counter: No
- Convenience kit: No
- Combination product: No
- HCT/P: No
- Premarket exempt: No
- Serial number: No
- Expiration date: No
- Manufacturing date: No