Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

FHC, INC.

United States·US-MF-000012111

Last updated September 17, 2026

Information

Country
United States
Address
1201, Main St, Bowdoin, United States
LinkedIn
—
Facebook
—
Phone
+1(800)326-2905
PRRC Contact
Kelly Moeykens
EUDAMED SRN
US-MF-000012111
FDA FEI Number
3002250546
DUNS Number
108179458

Catalogue (714)

Page 13 of 15
DeviceModel / ReferenceRegistriesClassStatus
microTargeting™ Single Electrode Insertion Tube Set 66-IT-4015N-00621
FDA UDI
Class IIActive
microTargeting™ WayPoint™ Inserter Kit 66-WP-ID-02-00532
FDA UDI
Class IIActive
microTargeting™ Drive Sterilization Case 67-00-4B-00354
FDA UDI
Class IIUnknown
STar™ Drive M/E System ST-DS-ME-00443
FDA UDI
Class IIActive
WayPoint™ Entry Offset Mounting Hub 66-MP-EH-00726
FDA UDI
Class IIActive
microTargeting™ Multi-Oblique Tool Guide 66-MO-03-00548
FDA UDI
Class IIActive
microTargeting™ Insertion Tube FC1019-00113
FDA UDI
Class IIUnknown
STar™ Drive Frame Adapter FC8006-00832
FDA UDI
Class IIActive
microTargeting™ Electrode 22670-00878
FDA UDI
Class IIActive
microTargeting™ Position Display Encoder 66-DA-EN-02-00444
FDA UDI
Class IIActive
microTargeting™ Electrode FC2002-00127
FDA UDI
Class IIUnknown
Nexprobe® NP-1000-00770
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZP(SP)(AR5)-00472
FDA UDI
Class IIActive
microTargeting™ Frame Adapter 66-FA-RD-00383
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWLP(BP)(BP8)-00400
FDA UDI
Class IIActive
WayPoint™ Fiducial Placement Template 66-DA-FT-03-00839
FDA UDI
Class IIUnknown
microTargeting™ Electrodes FC5000-00117
FDA UDI
Class IIUnknown
microTargeting™ Array Electrode Carrier Set 66-AC-AR-00525
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(DB9)-00529
FDA UDI
Class IIActive
microTargeting™ Electrodes FC2004-00129
FDA UDI
Class IIUnknown
microTargeting™ Single Electrode Insertion Tube Set 66-IT-4015-00369
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(DB12)-00521
FDA UDI
Class IIActive
microTargeting™ Platform Accessory MP-KIT-MC-00414
FDA UDI
Class IIActive
STar™ Drive Platform Adapter Kit 70-FA-SF-00220
FDA UDI
Class IIUnknown
microTargeting™ Electrode FC2001-00749
FDA UDI
Class IIActive
microTargeting™ NexFrame® Insertion Tube Kit 66-IT-4010S-00848
FDA UDI
Class IIActive
microTargeting™ STar™ Insertion Tube 70-IT-AR5P-00230
FDA UDI
Class IIActive
STar™ Drive Lead Measurement Fixture 70-AC-MT-01-00275
FDA UDI
Class IIActive
Guideline 4000 5.0™ Motor & Encoder C0235-00682
FDA UDI
Class IIActive
microTargeting™ Drive Array Clamp 66-AC-NC-00465
FDA UDI
Class IIActive
microTargeting™ Insertion Tube FC9003-00901
FDA UDI
Class IIActive
microTargeting™ Drive Mount and Guide 66-DM-01-00434
FDA UDI
Class IIActive
STar™ Drive Electrode Carrier FC8008-00083
FDA UDI
Class IIUnknown
WayPoint™ Standard Mounting Hub 66-MP-MH-00605
FDA UDI
Class IIUnknown
microTargeting™ Sterile Drape Sleeves FC1004-00904
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(BP11)-00500
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(AR31)-00817
FDA UDI
Class IIActive
WayPoint™ Standoff Wrench 66-WP-SW-00728
FDA UDI
Class IIActive
Unibody™ Bone Fiducials (13mm) FM-4013-00877
FDA UDI
Class IIActive
WayPoint™ Burr Hole Entry Marker Tool 66-MP-EM-00300
FDA UDI
Class IIUnknown
microTargeting™ Insertion Tube Set 66-IT-09-00410
FDA UDI
Class IIActive
WayPoint™ Navigator 66-WP-NV(4.5)-00699
FDA UDI
Class IIActive
microTargeting™ Insertion Tube 66-IT-3000-00381
FDA UDI
Class IIActive
microTargeting™ Electrode Lead Cable C0230-00690
FDA UDI
Class IIActive
microTargeting™ Electrode Cable FC1020-00151
FDA UDI
Class IIActive
microTargeting™ Single Procedure Kit KTF1001-00890
FDA UDI
Class IIActive
microTargeting™ Electrode and Insertion Tube Kit FC7100-00132
FDA UDI
Class IIUnknown
microTargeting™ Platform Accessory MP-KIT-MD-00415
FDA UDI
Class IIActive
microTargeting™ Multi-Oblique Tool Guide 66-MO-01-00546
FDA UDI
Class IIActive
NEXDRIVE™ w/DIG MI-1000-00771
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (29)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Oct 4, 2024Z-0312-2025—open, classified

A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244517 of P/N 66-IT-06P. Use of the product with a spacer tube which is too long could result in intercranial hemorrhaging and brain damage.

Jun 17, 2020Z-2540-2020—terminated

An electrical sub-circuit was not properly connected. Its purpose is to eliminate the possibility of interference with proper performance of the Guideline 5 Main Processing Unit, if an ESD event (greater than 6kV) were to occur.

May 10, 2018Z-2350-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2349-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2348-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2352-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2354-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2355-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2345-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2358-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2351-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2346-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2359-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2357-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2347-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2353-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2356-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

Mar 30, 2010Z-0311-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0312-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0313-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0314-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Dec 28, 2009Z-1143-2010—terminated

The raster tab for the GL4K version 1.4 software may assign incorrect depths for waveform recordings and if used to identify the implantation target for the DBS lead, the implant may be placed in the wrong location.

Oct 20, 2008Z-0497-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0498-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0499-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 8, 2008Z-0486-2009—terminated

Measuring fixture is incorrectly graduated.

Oct 31, 2005Z-0180-06—terminated

Power Assist microTargeting System may advance beyond intended target

Oct 31, 2005Z-0179-06—terminated

Power Assist microTargeting System may advance beyond intended target

Mar 14, 2005Z-0895-05—terminated

Potential for non-sterile pin to contaminate sterile field