Catalogue (714)

Page 2 of 15
DeviceModel / ReferenceRegistriesClassStatus
microTargeting™ STar™ Drive Insertion Tube Set 70-IT-AR-00217
FDA UDI
Class IActive
microTargeting™ Insertion Tube Set FC1036-00763
FDA UDI
Class IIActive
microTargeting™ Platform MP-KIT-P-SB-00592
FDA UDI
Class IIActive
STar™ Drive Electrode Carrier Hex Wrench 70-AC-HW-00555
FDA UDI
Class IIActive
microTargeting™ Electrode FC1002-00747
FDA UDI
Class IIActive
microTargeting™ Electrode Cable FC1020-00139
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWXN(AR)(MP1)-00744
FDA UDI
Class IIActive
microTargeting™ Electrode FC5000-00888
FDA UDI
Class IIActive
microTargeting™ Platform MP-KIT-P-ES-00597
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(AR17)-00470
FDA UDI
Class IIActive
microTargeting™ Electrode MTDPBN(PA)(DB2)-00315
FDA UDI
Class IIActive
microTargeting™ Array Electrode Carrier and Clamp FC1021-00061-
FDA UDI
Class IIActive
WayPoint™ Navigator 66-WP-NV(4.4)-00613
FDA UDI
Class IIUnknown
microTargeting™ Electrode MTDWZN(BP)(BP11)-00925
FDA UDI
Class IIActive
microTargeting™ Insertion Tube FC9002-00767
FDA UDI
Class IIActive
STarFix™ Designer C0265-00860
FDA UDI
Class IIActive
microTargeting™ Insertion Tube Set 66-IT-KH1P-00296
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZP(AR)(MP7)-00923
FDA UDI
Class IIActive
STar™ Drive Frame Adapter 70-FA-GP-00618
FDA UDI
Class IIActive
microTargeting™ Array Electrode Carrier and Clamp FC1021-00061
FDA UDI
Class IIUnknown
microTargeting™ Insertion Tube FC9002-00122
FDA UDI
Class IIUnknown
STar™ Drive MA System ST-DS-MA-00441
FDA UDI
Class IIActive
WayPoint™ Standard Mounting Hub 66-MP-MH-00305
FDA UDI
Class IIUnknown
WayPoint™ Entry Offset Mounting Hub 66-MP-EH-00298
FDA UDI
Class IIUnknown
microTargeting™ Frame Adapter 66-FA-LX-01-00387
FDA UDI
Class IIUnknown
microTargeting™ Controller with Encoder FC1007-00143
FDA UDI
Class IIActive
microTargeting™ Electrode 45335Z-00799
FDA UDI
Class IIActive
microTargeting™ Electrode and Insertion Tube FC4000-00753
FDA UDI
Class IIActive
microTargeting™ STar™ Array Insertion Tube Extractor 70-CN-ET-00236
FDA UDI
Class IActive
microTargeting™ Electrode FC2003-00884
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(AR39)-00497
FDA UDI
Class IIActive
microTargeting™ Electrode MTDPBP(LS)(LS3)-00326
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZP(AR)(AR7)-00865
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWBP(AO)(AO1)-00542
FDA UDI
Class IIActive
microTargeting™ Verfication Probe 66-IT-VP-00371
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(MD1)-00509
FDA UDI
Class IIActive
STar™ Drive Accesories Kit 70-AC-KT-MA-00282
FDA UDI
Class IIActive
STar™ Drive Positioner 70-DP-OS-00238
FDA UDI
Class IIActive
microTargeting™ WayPoint™ Inserter Kit 66-WP-ID-01-00336
FDA UDI
Class IIActive
microTargeting™ Lumen Cleaning Tool 66-CN-RT-00447
FDA UDI
Class IIActive
microTargeting™ Spacer Tube 66-PT(SJ1)-00253
FDA UDI
Class IIActive
STar™ Drive Frame Adapter FC8004-00830
FDA UDI
Class IIActive
microTargeting™ Platform Accessory MP-KIT-MB-00413
FDA UDI
Class IIUnknown
STar™ Drive Frame Adapter 70-FA-BL-00235
FDA UDI
Class IIActive
STar™ Drive Lead Holder Screw 70-CN-DB-01-00260
FDA UDI
Class IIActive
microTargeting™ Spacer Tube 66-PT(JN11)-00262
FDA UDI
Class IIActive
microTargeting™ Frame Adapter FC1010-00738
FDA UDI
Class IIActive
microTargeting™ Electrode 34625Z-00249
FDA UDI
Class IIActive
microTargeting™ Electrode and Insertion Tube Kit KTF1002-00134
FDA UDI
Class IUnknown
WayPoint™ Surgical Kit 66-WP-MR-00317
FDA UDI
Class IIUnknown

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (29)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Oct 4, 2024Z-0312-2025—open, classified

A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244517 of P/N 66-IT-06P. Use of the product with a spacer tube which is too long could result in intercranial hemorrhaging and brain damage.

Jun 17, 2020Z-2540-2020—terminated

An electrical sub-circuit was not properly connected. Its purpose is to eliminate the possibility of interference with proper performance of the Guideline 5 Main Processing Unit, if an ESD event (greater than 6kV) were to occur.

May 10, 2018Z-2350-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2349-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2348-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2352-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2354-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2355-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2345-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2358-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2351-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2346-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2359-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2357-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2347-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2353-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2356-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

Mar 30, 2010Z-0311-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0312-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0313-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0314-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Dec 28, 2009Z-1143-2010—terminated

The raster tab for the GL4K version 1.4 software may assign incorrect depths for waveform recordings and if used to identify the implantation target for the DBS lead, the implant may be placed in the wrong location.

Oct 20, 2008Z-0497-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0498-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0499-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 8, 2008Z-0486-2009—terminated

Measuring fixture is incorrectly graduated.

Oct 31, 2005Z-0180-06—terminated

Power Assist microTargeting System may advance beyond intended target

Oct 31, 2005Z-0179-06—terminated

Power Assist microTargeting System may advance beyond intended target

Mar 14, 2005Z-0895-05—terminated

Potential for non-sterile pin to contaminate sterile field