FHC, INC.

United States·US-MF-000012111

Last updated September 17, 2026

Information

Country
United States
Address
1201, Main St, Bowdoin, United States
LinkedIn
—
Facebook
—
Phone
+1(800)326-2905
PRRC Contact
Kelly Moeykens
EUDAMED SRN
US-MF-000012111
FDA FEI Number
3002250546
DUNS Number
108179458

Catalogue (714)

Page 3 of 15
DeviceModel / ReferenceRegistriesClassStatus
microTargeting™ Electrode MTDPXN(EP)(BP8)-00570
FDA UDI
Class IIActive
microTargeting™ WayPoint Anchors 66-WP-AN5-00316
FDA UDI
Class IIActive
microTargeting™ Microtable™ Platform – Staged 66-MT-D3-00645
FDA UDI
Class IIUnknown
microTargeting™ Electrode MTSWBN(LX1)-00488
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWLP(BP)(BP16)-00942
FDA UDI
Class IIActive
microTargeting™ Electrode MTBPBN(DT1)-00671
FDA UDI
Class IIActive
microTargeting™ Platform MP-KIT-P-EP-00591
FDA UDI
Class IIActive
microTargeting™ Electrode MTBWAP(JJ2)-00309
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(AO6)-00468
FDA UDI
Class IIActive
microTargeting™ Platform Adapter Kit 66-FA-SF-00295
FDA UDI
Class IIActive
microTargeting™ Insertion Tube 66-IT(IT1)-00697
FDA UDI
Class IIActive
NEXDRIVE™ w/DIG MI-1000-00870
FDA UDI
Class IIActive
microTargeting™ Electrode Lead Cable C0232-00781
FDA UDI
Class IIActive
microTargeting™ Platform MP-KIT-P-BI-00590
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZP(BP)(BP11)-00924
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(BP20)-00568
FDA UDI
Class IIActive
microTargeting™ Electrode 22670-00124
FDA UDI
Class IIUnknown
microTargeting™ Electrode 5700R-00578
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT-AR21P-00583
FDA UDI
Class IIActive
microTargeting™ Frame Adapter 66-FA-RD-01-00378
FDA UDI
Class IIUnknown
Guideline 4000 5.0™ 3m Interface Cable C0221-00681
FDA UDI
Class IIActive
Lower Lead Depth Stop FC8014-00819
FDA UDI
Class IIUnknown
microTargeting™ Insertion Tube 66-IT(FP4)-00665
FDA UDI
Class IIActive
microTargeting™ Platfrom Accessory MP-KIT-A-MS-00374
FDA UDI
Class IIActive
microTargeting™ USB to Serial Adapter MT-LPP-CONV-00285
FDA UDI
Class IIActive
microTargeting™ Cleaning Brushes 66-CN-BR-00455
FDA UDI
Class IIActive
microTargeting™ Electrode MTSPLN(RD1)-00486
FDA UDI
Class IIActive
STar™ Drive MA FC8001-00148
FDA UDI
Class IIUnknown
microTargeting™ Insertion Tube Set FC1036-00114
FDA UDI
Class IIUnknown
microTargeting™ Insertion Tube with Stylet 66-IT(ES5)-00531
FDA UDI
Class IIActive
microTargeting™ Insertion Tube 66-IT-BP8P-00332
FDA UDI
Class IIActive
Lead Adapter, For use with Multi-Lead Trial Cable to Guideline System MT-LA-01-00610
FDA UDI
Class IIActive
microTargeting™ Insertion Tube FC9002-00900
FDA UDI
Class IIActive
microTargeting™ Insertion Tube 66-IT-AR6P-00342
FDA UDI
Class IIActive
microTargeting™ Multi-Oblique Tool Guide 66-MO-06-00630
FDA UDI
Class IIActive
microTargeting™ Controller 66-EL-MS-04-00541
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZN(AR)(AR7)-00863
FDA UDI
Class IIActive
microTargeting™Array Electrode Insertion Tube Set FC1012-00153
FDA UDI
Class IIUnknown
microTargeting™ Electrode 22670R-00242
FDA UDI
Class IIActive
microTargeting™ Electrode MTTWLP(ZK2)-00519
FDA UDI
Class IIActive
STar™ Drive Insertion Tube Set 70-IT-04-00218
FDA UDI
Class IActive
WayPoint™ Anchors 66-WP-AN1-00623
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWXN(BP)(BP7)-00406
FDA UDI
Class IIActive
microTargeting™ Platform Accessory MP-KIT-A-MP-00367
FDA UDI
Class IIActive
microTargeting™ Spacer Tube 66-PT(SJ3)-00247
FDA UDI
Class IIActive
microTargeting™ Electrode 34680R-00250
FDA UDI
Class IIActive
microTargeting™ Electrode 35385Z-00796
FDA UDI
Class IIActive
Nexframe Screws SR-10-00804
FDA UDI
Class IIActive
microTargeting™ Electrode 44935L-00573
FDA UDI
Class IIActive
microTargeting™ Electrode MTDPBN(PS)(PS1)-00632
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (29)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Oct 4, 2024Z-0312-2025—open, classified

A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244517 of P/N 66-IT-06P. Use of the product with a spacer tube which is too long could result in intercranial hemorrhaging and brain damage.

Jun 17, 2020Z-2540-2020—terminated

An electrical sub-circuit was not properly connected. Its purpose is to eliminate the possibility of interference with proper performance of the Guideline 5 Main Processing Unit, if an ESD event (greater than 6kV) were to occur.

May 10, 2018Z-2350-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2349-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2348-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2352-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2354-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2355-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2345-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2358-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2351-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2346-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2359-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2357-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2347-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2353-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2356-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

Mar 30, 2010Z-0311-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0312-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0313-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0314-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Dec 28, 2009Z-1143-2010—terminated

The raster tab for the GL4K version 1.4 software may assign incorrect depths for waveform recordings and if used to identify the implantation target for the DBS lead, the implant may be placed in the wrong location.

Oct 20, 2008Z-0497-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0498-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0499-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 8, 2008Z-0486-2009—terminated

Measuring fixture is incorrectly graduated.

Oct 31, 2005Z-0180-06—terminated

Power Assist microTargeting System may advance beyond intended target

Oct 31, 2005Z-0179-06—terminated

Power Assist microTargeting System may advance beyond intended target

Mar 14, 2005Z-0895-05—terminated

Potential for non-sterile pin to contaminate sterile field