FHC, INC.

United States·US-MF-000012111

Last updated September 17, 2026

Information

Country
United States
Address
1201, Main St, Bowdoin, United States
LinkedIn
—
Facebook
—
Phone
+1(800)326-2905
PRRC Contact
Kelly Moeykens
EUDAMED SRN
US-MF-000012111
FDA FEI Number
3002250546
DUNS Number
108179458

Catalogue (714)

Page 8 of 15
DeviceModel / ReferenceRegistriesClassStatus
microTargeting™ Insertion Tube with Stylet 66-IT(AR14)-00469
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZP(AO)(AO9)-00448
FDA UDI
Class IIActive
microTargeting™ Insertion Tube 66-IT(FP3)-00664
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT-15P-00821
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(MD2)-00493
FDA UDI
Class IIActive
microTargeting™ Drive Hex Wrench 66-CN-HX-00449
FDA UDI
Class IIActive
MacroStim Interface (MSI) 66-EL-MI-00422
FDA UDI
Class IIActive
microTargeting™ Directional Lead Holder 70-CN-DL-00701
FDA UDI
Class IIActive
microTargeting™ Insertion Tube 66-IT-MR3-00803
FDA UDI
Class IIUnknown
microTargeting™ Platform MP-KIT-P-U3-00593
FDA UDI
Class IIActive
microTargeting™ Electrode 44375Z-00798
FDA UDI
Class IIActive
microTargeting™ Drive System MT-DS-01-00350
FDA UDI
Class IIActive
microTargeting™ Electrode 45375Z-00800
FDA UDI
Class IIActive
WayPoint™ Standoff Wrench 66-WP-SW-00351
FDA UDI
Class IIUnknown
WayPoint™ Navigator C0240-00783
FDA UDI
Class IIActive
microTargeting™ Frame Adapter 66-FA-RD-02-00376
FDA UDI
Class IIUnknown
microTargeting™ Electrode MTDPZN(PA)(MP1)-00641
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(AR38)-00496
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(BP16)-00501
FDA UDI
Class IIActive
microTargeting™ Platform NeuroBlate® Adaptor Kit 66-WP-NB-00344
FDA UDI
Class IIUnknown
microTargeting™ STar™ Insertion Tube 70-IT-ARP-00227
FDA UDI
Class IIActive
Waypoint™ Navigator C0244-00787
FDA UDI
Class IIActive
microTargeting™ Spacer, 11mm 1x 66-CN-BP11-00445
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(DB10)-00516
FDA UDI
Class IIActive
Unibody™ Bone Fiducials (7mm) FM-4007-00773
FDA UDI
Class IIUnknown
microTargeting™Spacer Tube 66-PT(BP10)-00662
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZN(SS)(BP8)-00660
FDA UDI
Class IIActive
microTargeting™ Electrode 34680-00125
FDA UDI
Class IIUnknown
microTargeting™ Insertion Tube with Stylet 66-IT(AO9)-00647
FDA UDI
Class IIActive
microTargeting™ STar™ Insertion Tube 70-IT(AR5)-00652
FDA UDI
Class IIActive
microTargeting™ Frame Adapter FC1009-00103
FDA UDI
Class IIUnknown
microTargeting™ Multi-Oblique Tool Guide 66-MO-04-00549
FDA UDI
Class IIActive
microTargeting™ Matrix Guide Bushings 66-AC-MB-00483
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWLN(BP)(BP8)-00396
FDA UDI
Class IIActive
microTargeting™ Drive Accessories Kit 66-AC-KT-00491
FDA UDI
Class IIActive
microTargeting™ Electrode MTDWZP(AR)(MP3)-00452
FDA UDI
Class IIUnknown
microTargeting™ Verification Probe 66-IT-VP-03-00845
FDA UDI
Class IIActive
microTargeting™ Controller Storage Case 66-DA-SC-00438
FDA UDI
Class IIUnknown
microTargeting™ Electrode MTDWLN(BP)(BP16)-00941
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(FP1)-00526
FDA UDI
Class IIActive
microTargeting™ Electrode MTDPZP(EP)(BP8)-00348
FDA UDI
Class IIActive
WayPoint™ Planner 66-WP-PL-00437
FDA UDI
Class IIUnknown
STar™ Drive Lead Adapter 70-CN-DB-00264
FDA UDI
Class IIActive
WayPoint™ Entry Offset Mounting Hub 66-MP-EH-00604
FDA UDI
Class IIUnknown
microTargeting™ Digital Display Unit (DDU) 66-EL-MS-01-00407
FDA UDI
Class IIActive
microTargeting™ Array Clamp 66-AC-SC-00458
FDA UDI
Class IIActive
microTargeting™ Electrode FC2001-00882
FDA UDI
Class IIActive
microTargeting™ Electrode 5035L-00576
FDA UDI
Class IIActive
microTargeting™ Insertion Tube with Stylet 66-IT(AR29)-00866
FDA UDI
Class IIActive
microTargeting™ Stylet 66-IT(ST14)-00476
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (29)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Oct 4, 2024Z-0312-2025—open, classified

A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244517 of P/N 66-IT-06P. Use of the product with a spacer tube which is too long could result in intercranial hemorrhaging and brain damage.

Jun 17, 2020Z-2540-2020—terminated

An electrical sub-circuit was not properly connected. Its purpose is to eliminate the possibility of interference with proper performance of the Guideline 5 Main Processing Unit, if an ESD event (greater than 6kV) were to occur.

May 10, 2018Z-2350-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2349-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2348-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2352-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2354-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2355-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2345-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2358-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2351-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2346-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2359-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2357-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2347-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2353-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

May 10, 2018Z-2356-2018—terminated

The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

Mar 30, 2010Z-0311-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0312-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0313-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Mar 30, 2010Z-0314-2011—terminated

Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

Dec 28, 2009Z-1143-2010—terminated

The raster tab for the GL4K version 1.4 software may assign incorrect depths for waveform recordings and if used to identify the implantation target for the DBS lead, the implant may be placed in the wrong location.

Oct 20, 2008Z-0497-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0498-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 20, 2008Z-0499-2009—terminated

Mislabeled: May contain an electrode longer than labeled size

Oct 8, 2008Z-0486-2009—terminated

Measuring fixture is incorrectly graduated.

Oct 31, 2005Z-0180-06—terminated

Power Assist microTargeting System may advance beyond intended target

Oct 31, 2005Z-0179-06—terminated

Power Assist microTargeting System may advance beyond intended target

Mar 14, 2005Z-0895-05—terminated

Potential for non-sterile pin to contaminate sterile field