Accessories Temperature Probe Inspire
Accessories Temperature Probe Inspire is a cardiopulmonary bypass system (FDA Class II; FDA product code DTQ, Console, Heart-Lung Machine, Cardiopulmonary Bypass) made by LivaNova Deutschland GmbH, cleared under FDA 510(k) K071318 on 6 Jul 2007 and listed in FDA GUDID since 8 May 2021 (UDI-DI 04033817903147), active as of 23 Oct 2026. 13 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number04033817903147 | Date8 May 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK071318 | Date6 Jul 2007 | StatusActive |
Official records
- AccessGUDID record 04033817903147
- FDA 510(k) database K071318
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K071318 decided 6 Jul 2007 Active
- FDA GUDID UDI-DI 04033817903147 listed 8 May 2021 Listed
Recalls
-
- Terminated Z-1119-2020
Incorrect labeling; it was identified that some Datapad devices contained incorrect labels. Specifically the manufacturing date in the production identifier was incorrect and the manufacturing date on the unique device identifier label was labeled in the format of yy-mm-dd instead of yyyy-mm-dd.
-
- Terminated Z-2866-2016
Sorin/LivaNova is initiating a field correction on the S5 Heart-lung machine because of the potential for failure of the Uninterruptible Power Supply.
-
- Terminated Z-0856-2014
Sorin is initiating a field correction on S5/C5 Heart-lung machine and CP5 centrifugal pump system due to reports of pump speed control knob failures resulting in no response.
-
- Terminated Z-0142-2014
Sorin Group is recalling certain models of S5 Perfusion Systems due to malfunction of cardioplegia control.
-
- Terminated Z-0274-2013
- Terminated Z-0275-2013
- Terminated Z-0272-2013
- Terminated Z-0273-2013
Sorin Group USA, Inc. has issued an Urgent Field Safety Notice regarding certain serial numbers of the Sorin Group S5 Perfusion System due to reports of a "Fault in motor controller" alarm message displayed on the system panel. This could lead to unintended pump stoppage which may result in permanent impairment or life-threatening injury. An out of specification electrical component was determin
-
- Terminated Z-0271-2013
Sorin Group USA, Inc. has issued an Urgent Field Safety Notice regarding certain serial numbers of the Sorin Group S5 Perfusion System due to reports of a "Fault in motor controller" alarm message displayed on the system panel. This could lead to unintended pump stoppage which may result in permanent impairment or life-threatening injury. An out of specification electrical component was determi
-
- Terminated Z-1325-2012
- Terminated Z-1327-2012
- Terminated Z-1328-2012
- Terminated Z-1326-2012
The pump speed control knob is attached to the shaft of an encoder that is used to adjust the speed. Insufficient lubrication within the encoder increases friction over time making it more difficult to turn the pump speed control knob. Excessive friction causes premature wear of the encoder shaft which can result in a stuck shaft.
Timeline
- Recall initiated FDA recalls Z-0274-2013
- Recall initiated FDA recalls Z-0275-2013
- Recall initiated FDA recalls Z-0271-2013
- Recall initiated FDA recalls Z-0272-2013
- Recall initiated FDA recalls Z-0273-2013
- Recall initiated FDA recalls Z-0142-2014
- Recall initiated FDA recalls Z-0856-2014
- Recall initiated FDA recalls Z-2866-2016
- Recall initiated FDA recalls Z-1119-2020
- Listed FDA GUDID 04033817903147
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Accessories
- Generic name
- Cardiopulmonary bypass system, roller type
- Model / reference
- Temperature Probe Inspire
- Primary DI / UDI-DI
- 04033817903147
- 510(k) Number
- FDA product code
- DTQ
- GMDN term
- Cardiopulmonary bypass system, roller type
- Device class
- Class II
- Regulation number
- 870.4220
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code DTQ (CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS).
- MAQUET CARDIOHELP CARDIOHELP Base Unit 70104.7999 by Maquet Cardiopulmonary AG
- SORIN C5 SYSTEM; 85/C5 MAST ROLLER PUMP SYSTEM 150(1X RP 150 AND CONTROL PANEL WITH CONNECTING CABLES); S5/C5 MAST ROLLE by Sorin Group Deutschland GmbH
- Century Perfusion System by Century Hlm, LLC
- STOCKERT CENTRIFUGAL PUMP CONSOLE by Stockert Instrumente GmbH
- Terumo Advanced Perfusion System 1 by Terumo Cardiovascular Systems Corporation
- STOCKERT S5 SYSTEM, STOCKERT GAS BLENDER by Sorin Group Deutschland GmbH
- SIII ALARM AMPLIFIER by Stockert Instrumente GmbH
- LIFEBRIDGE B2T, MODEL 7001 by Lifebridge Medizintechnik AG
- CENTRIMED SYSTEM 1 W/MANUAL PUMP DRIVE by Centrimed Corp.
- MAQUET CARDIOHELP FBS 3/8" x 3/32" L0.9 70104.8001 by Maquet Cardiopulmonary AG