Skip to content

Accessories Temperature Probe Kids

by LivaNova Deutschland GmbH

Accessories Temperature Probe Kids is a cardiopulmonary bypass system (FDA Class II; FDA product code DTQ, Console, Heart-Lung Machine, Cardiopulmonary Bypass) made by LivaNova Deutschland GmbH, cleared under FDA 510(k) K071318 on 6 Jul 2007 and listed in FDA GUDID since 8 May 2021 (UDI-DI 04033817903130), active as of 23 Oct 2026. 13 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

13 closed

Documents

510(k) K071318

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04033817903130 UDI-DI Date8 May 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK071318 Date6 Jul 2007DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K071318 decided 6 Jul 2007 Active
  • FDA GUDID UDI-DI 04033817903130 listed 8 May 2021 Listed

Recalls

13 recalls · FDA

    • Terminated Z-1119-2020 FDA Class III initiated 28 Jan 2019

    Incorrect labeling; it was identified that some Datapad devices contained incorrect labels. Specifically the manufacturing date in the production identifier was incorrect and the manufacturing date on the unique device identifier label was labeled in the format of yy-mm-dd instead of yyyy-mm-dd.

    • Terminated Z-2866-2016 FDA Class II initiated 25 Aug 2016

    Sorin/LivaNova is initiating a field correction on the S5 Heart-lung machine because of the potential for failure of the Uninterruptible Power Supply.

    • Terminated Z-0856-2014 FDA Class II initiated 4 Dec 2013

    Sorin is initiating a field correction on S5/C5 Heart-lung machine and CP5 centrifugal pump system due to reports of pump speed control knob failures resulting in no response.

    • Terminated Z-0142-2014 FDA Class II initiated 24 Sep 2013

    Sorin Group is recalling certain models of S5 Perfusion Systems due to malfunction of cardioplegia control.

  • 4 recalls, same reason

    • Terminated Z-0274-2013 FDA Class II initiated 19 Sep 2012
    • Terminated Z-0275-2013 FDA Class II initiated 19 Sep 2012
    • Terminated Z-0272-2013 FDA Class II initiated 19 Sep 2012
    • Terminated Z-0273-2013 FDA Class II initiated 19 Sep 2012

    Sorin Group USA, Inc. has issued an Urgent Field Safety Notice regarding certain serial numbers of the Sorin Group S5 Perfusion System due to reports of a "Fault in motor controller" alarm message displayed on the system panel. This could lead to unintended pump stoppage which may result in permanent impairment or life-threatening injury. An out of specification electrical component was determin

    • Terminated Z-0271-2013 FDA Class II initiated 19 Sep 2012

    Sorin Group USA, Inc. has issued an Urgent Field Safety Notice regarding certain serial numbers of the Sorin Group S5 Perfusion System due to reports of a "Fault in motor controller" alarm message displayed on the system panel. This could lead to unintended pump stoppage which may result in permanent impairment or life-threatening injury. An out of specification electrical component was determi

  • 4 recalls, same reason

    • Terminated Z-1325-2012 FDA Not yet classified initiated 23 Feb 2012
    • Terminated Z-1327-2012 FDA Not yet classified initiated 23 Feb 2012
    • Terminated Z-1328-2012 FDA Not yet classified initiated 23 Feb 2012
    • Terminated Z-1326-2012 FDA Not yet classified initiated 23 Feb 2012

    The pump speed control knob is attached to the shaft of an encoder that is used to adjust the speed. Insufficient lubrication within the encoder increases friction over time making it more difficult to turn the pump speed control knob. Excessive friction causes premature wear of the encoder shaft which can result in a stuck shaft.

Timeline

15 dated events

  1. Recall initiated FDA recalls Z-0274-2013
  2. Recall initiated FDA recalls Z-0275-2013
  3. Recall initiated FDA recalls Z-0271-2013
  4. Recall initiated FDA recalls Z-0272-2013
  5. Recall initiated FDA recalls Z-0273-2013
  6. Recall initiated FDA recalls Z-0142-2014
  7. Recall initiated FDA recalls Z-0856-2014
  8. Recall initiated FDA recalls Z-2866-2016
  9. Recall initiated FDA recalls Z-1119-2020
  10. Listed FDA GUDID 04033817903130

5 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Accessories
Generic name
Cardiopulmonary bypass system, roller type
Model / reference
Temperature Probe Kids
Primary DI / UDI-DI
04033817903130
510(k) Number
FDA product code
DTQ
GMDN term
Cardiopulmonary bypass system, roller type
Device class
Class II
Regulation number
870.4220
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code DTQ (CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS).

Other devices from LivaNova Deutschland GmbH

See all devices from LivaNova Deutschland GmbH →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)